Radyne MM200 Installation And Operation Manual page 173

Mm200 high speed microwave modem
Table of Contents

Advertisement

MM200 High-Speed Microwave Modem
radMM200RxInterfaceDataInvert INTEGER,
radMM200RxInterfaceTerrestrialLoopback INTEGER,
radMM200RxInterfacePRBS INTEGER,
radMM200RxInterfaceMajorAlarmMask INTEGER,
radMM200RxInterfaceMinorAlarmMask INTEGER,
radMM200RxInterfaceJitterControl INTEGER,
radMM200RxInterfaceByteGapping INTEGER
}
radMM200RxInterfaceNVIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS
STATUS current
DESCRIPTION
"Index into the MM200 Rx interface on-volatile table."
::= { radMM200RxInterfaceNVStatusEntry 1 }
radMM200RxInterfacePID OBJECT-TYPE
SYNTAX INTEGER (0..8192)
MAX-ACCESS
STATUS current
DESCRIPTION
"Selects the interface Program Id. If not in 188
byte framing mode (unframed), this PID steers the
packet to the appropriate interface. In the MM200,
only one framed interface is allowed and its packets
are sent in the clear, without modifications. The
Null PID and the PIDs of the unframed interfaces should
be unique. All packets PIDs not equal to these will
be sent to the framed interface."
::= { radMM200RxInterfaceNVStatusEntry 2 }
radMM200RxInterfaceDataRate OBJECT-TYPE
SYNTAX INTEGER (64000..20000000)
MAX-ACCESS
STATUS current
DESCRIPTION
"Selects the data rate in BPS of the individual
interfaces. The data rate is T3, E3, or STS1
for G.703
155.52M BPS for OC3 and STM1
1.544M BPS for T1
2.048M BPS for E1
Variable for parallel and ASI
64K BPS for 8 channel DS0
The range is between 64K to 200M BPS"
::= { radMM200RxInterfaceNVStatusEntry 3 }
radMM200RxInterfaceControl OBJECT-TYPE
SYNTAX ControlType
MAX-ACCESS
STATUS current
DESCRIPTION
"Controls the Rx interface enabling."
::= { radMM200RxInterfaceNVStatusEntry 4 }
radMM200RxInterfaceType OBJECT-TYPE
SYNTAX INTEGER {
TM086 – Rev 4.1
read-only
read-write
read-write
read-write
asi(1)
aasi(2)
t3(3),
e3(4),
sts1(5),
t1(6),
e1(7),
ds0x8(8),
ds0x7A(9),
Appendix B
B-25

Advertisement

Table of Contents
loading