Radyne MM200 Installation And Operation Manual page 135

Mm200 high speed microwave modem
Table of Contents

Advertisement

MM200 High-Speed Microwave Modem
<1>
Interface Latched
Major Alarm1 Status
<1>
Interface Latched
Minor Alarm1 Status
<1>
Interface Card
<1>
Reserved
Opcode: <0x2163>
<1>
Selected interface
number
<1>
Selected
interface number
<1>
Jitter Control
Opcode: <0x2164>
TM086 – Rev. 4.1
Bit 1 = Interface FIFO empty
Bit 2 = PLL lock
Bit 3 = Interface data activity detect
Bit 4 = Interface clock activity detect
Bit 5 - 7 = Spare
0 = Pass, 1 = Fail
Bit 0 = Interface Test
Bit 1 - 7 = Spare
0 = Pass, 1 = Fail
Bit 0 = Interface FIFO full
Bit 1 = Interface FIFO empty
Bit 2 = PLL lock
Bit 3 = Interface data activity detect
Bit 4 = Interface clock activity detect
Bit 5 - 7 = Spare
0 = None
1 = ASI/AASI
2 = ASIS
3 = NASI
4 = T3E3
5 = T1E1
6 = DSO
7 = PAR
8 = OC3
9 = HSSI
10 = SMPTE
11 = P10BaseT
12 = T2E2
Spare
Query selected Rx interface jitter control
Command Data Field 1 Byte
0 = interface1
1 = interface2
2 = interface3
3 = interface4
Query Response
0 = interface1
1 = interface2
2 = interface3
3 = interface4
0 = Inch
1 = Slow
2 = Medium
3 = Fast
4 = Stamp2
5 = Stamp3
Query selected Rx interface byte gap
Command Data Field 1 Byte
Appendix A
A-35