"Minor Alarm 1 mask:
Bit 0 = Tx clock activity detect
Bit 1 = Tx data activity detect
Bit 2 = Frame lock
Bit 3 = Spare
Bit 4 = Spare
Bit 5 = Spare
Bit 6 = Spare
Bit 7 = Spare
0 = Mask, 1 = Allow"
::= { radMM200ModNVStatus 17 }
radMM200TxMinorAlarm2Mask OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
STATUS current
DESCRIPTION
"Minor Alarm 2 mask:
Bit 0..7 = Spares
0 = Mask, 1 = Allow"
::= { radMM200ModNVStatus 18 }
radMM200TxPRBS OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
prbs23(2),
prbs23m(3),
prbs15(4),
prbs15m(5)
}
MAX-ACCESS
STATUS current
DESCRIPTION
"Selects the pseudo-random bit sequence for link
testing."
::= { radMM200ModNVStatus 19 }
-- --------------------------------------------------------------------------------------------------------------------
-- --------------------------------------------------------------------------------------------------------------------
-- MM200 modulator status information.
radMM200TxMajorAlarm1Status OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this
to the value '00000000'B
Bit 0 = Glue logic FPGA fail
Bit 1 = Data FPGA fail
Bit 2-7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200ModStatus 1 }
radMM200TxMajorAlarm2Status OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the value '00000000'B
Bit 0..7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200ModStatus 2 }