MM200 High-Speed Microwave Modem
"Major Alarm 1 status. The agent initializes this to
the value '00000000'B
Bit 0 = Glue logic FPGA status
Bit 1 = Data FPGA status
Bit 2 = Signal lock detect
Bit 3 = Sync lock detect
Bit 4 = Data PLL lock detect
Bit 5-7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200DemodStatus 1 }
radMM200RxMajorAlarm2Status OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
STATUS current
DESCRIPTION
"Major Alarm 2 status. The agent initializes this to
the value '00000000'B
Bit 0-7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200DemodStatus 2 }
radMM200RxMinorAlarm1Status OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
STATUS current
DESCRIPTION
"Minor Alarm 1 status. The agent initializes this to
the value '00000000'B
Bit 0 = Spare
Bit 1 = Spare
Bit 2 = Spare
Bit 3 = Spare
Bit 4 = Spare
Bit 5 = Spare
Bit 6 = Spare
Bit 7 = Spare
0 = Pass, 1 = Fail"
::= { radMM200DemodStatus 3 }
radMM200RxMinorAlarm2Status OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
STATUS current
DESCRIPTION
"Minor Alarm 2 status. The agent initializes this to
the value '00000000'B
Bit 0..7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200DemodStatus 4 }
radMM200RxLatchedMajorAlarm1Status OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the value '00000000'B.
Bit 0 = Glue logic FPGA status
Bit 1 = Data FPGA status
Bit 2 = Signal lock detect
Bit 3 = Sync lock detect
Bit 4 = Data PLL lock detect
Bit 5-7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200DemodStatus 5 }