Radyne MM200 Installation And Operation Manual page 125

Mm200 high speed microwave modem
Table of Contents

Advertisement

MM200 High-Speed Microwave Modem
Status
<4>
Max Payload
<2>
Utilization
<4>
Bandwidth
<2>
Input Level
Opcode: <0x2140>
<1>
Selected interface
number
<1>
Selected
interface number
<1>
Interface Major
Alarm1 Status
<1>
Interface Minor
Alarm1 Status
<1>
Interface Latched
Major Alarm1
<1>
Interface Latched
Minor Alarm1 Status
<1>
Interface Card
TM086 – Rev. 4.1
Maximum payload at current demodulation
% utilization. Implied decimal point (i.e. 7985 means 79.85%)
Current bandwidth usage
Aggregate input level in dBm. Signed implied decimal point
(i.e. –265 means –26.5 dBm)
Query selected Tx interface status
Command Data Field 1 Byte
0 = interface1
1 = interface2
2 = interface3
3 = interface4
Query Response
0 = interface1
1 = interface2
2 = interface3
3 = interface4
0 = Pass, 1 = Fail
Bit 0 = Interface Test
Bit 1 - 7 = Spare
0 = Pass, 1 = Fail
Bit 0 = Interface FIFO full
Bit 1 = Interface FIFO empty
Bit 2 = PLL lock
Bit 3 = Interface data activity detect
Bit 4 = Interface clock activity detect
Bit 5 = Interface Tx input framing valid, added for AASI
Bit 6 = Interface signal loss, valid for some interfaces
Bit 7 = Spare
Status 0 = Pass, 1 = Fail
Bit 0 = Interface Test
Bit 1 - 7 = Spare
0 = Pass, 1 = Fail
Bit 0 = Interface FIFO full
Bit 1 = Interface FIFO empty
Bit 2 = PLL lock
Bit 3 = Interface data activity detect
Bit 4 = Interface clock activity detect
Bit 5 = Interface Tx input framing valid, added for AASI
Bit 6 = Interface signal loss, valid for some interfaces
Bit 7 = Spare
0 = None
1 = ASI/AASI
2 = ASIS
3 = NASI
4 = T3E3
Appendix A
A-25

Advertisement

Table of Contents
loading

Table of Contents