7-8
Physical and Operating Systems
200W Power Supply
Input Specifications
Rated Input Voltage
Rated Input Current
Rated Input Frequency
General Specifications
Input Power
Range Input Line
Holdup Time
Full Output Rating
Minimum Load
Ambient Temperature Range
Operating
Storage
Safety Standard
Input Transient Susceptibility:
Common and Differential Mode
(superimposed on AC line) Differential
Mode
Table 7-6
200W Power Supply Specifications
115 Voltage Setting
100 to 127 VAC
5.5A
50 to 60 Hz
310W
90 to 132 VAC
16 ms from zero crossing at 115 VAC 16 ms from zero crossing at 230 VAC
To 40 C and 5,000 ft.
To 32 C and 10,000 ft. (derate linearly)
1.5A on + 5V and +3.3V outputs; 0.1A
on +12V and +5V aux outputs
50 to 104 F
-40 to 149 F
rd
UL 1950 3
Edition; CSA 22.2 No. 950 3
2500V, 1 s, damped sinusoid 600V, 10 s pulse 20% step change in
AC input voltage
230 Voltage Setting
200 to 250 VAC
2.75A
50 to 60 Hz
310W
180 to 264 VAC
10 to 40 C
-40 to 65 C
rd
Edition, EN 60 950