Displaying Hwping Configuration; Hwping Configuration Examples; Icmp Test - H3C S5100-SI Operation Manual

Ethernet switches
Hide thumbs Also See for H3C S5100-SI:
Table of Contents

Advertisement

To do...
Enter system view
Enable the HWPing client
function
Create a HWPing test group
and enter its view
Enable the HWPing client to
send Trap messages
Configure the number of
consecutive unsuccessful
HWPing tests before Trap
output
Configure the number of
consecutive unsuccessful
HWPing probes before Trap
output

Displaying HWPing Configuration

To do...
Display test history
Display the results of the latest
test

HWPing Configuration Examples

ICMP Test

Network requirements
An H3C S5100-SI/EI series Ethernet switch serves as the HWPing client. A HWPing ICMP test between
the switch and another switch uses ICMP to test the round trip time (RTT) for packets generated by the
HWPing client to travel to and back from the destination switch.
Network diagram
Figure 1-2 Network diagram for the ICMP test
Use the command...
system-view
hwping-agent enable
hwping administrator-name
operation- tag
send-trap { all | { probefailure
| testcomplete | testfailure }* }
test-failtimes times
probe-failtimes times
Use the command...
display hwping history [ administrator-name
operation-tag ]
display hwping results [ administrator-name
operation-tag ]
1-15
Remarks
Required
By default, the HWPing client
function is disabled.
Required
By default, no test group is
configured.
Required
By default, Trap sending is
disabled.
Optional
By default, Trap messages are
sent each time a test fails.
Optional
By default, Trap messages are
sent each time a probe fails.