H3C S5100-SI Operation Manual page 746

Ethernet switches
Hide thumbs Also See for H3C S5100-SI:
Table of Contents

Advertisement

Network diagram
Figure 1-6 Network diagram for the Jitter test
Configuration procedure
Configure HWPing Server (Switch B):
# Enable the HWPing server and configure the IP address and port to listen on.
<Sysname> system-view
[Sysname] hwping-server enable
[Sysname] hwping-server udpecho 10.2.2.2 9000
Configure HWPing Client (Switch A):
# Enable the HWPing client.
<Sysname> system-view
[Sysname] hwping-agent enable
# Create a HWPing test group, setting the administrator name to administrator and test tag to Jitter.
[Sysname] hwping administrator Jitter
# Configure the test type as jitter
[Sysname-hwping-administrator-Jitter] test-type Jitter
# Configure the IP address of the HWPing server as 10.2.2.2.
[Sysname-hwping-administrator-Jitter] destination-ip 10.2.2.2
# Configure the destination port on the HWPing server.
[Sysname-hwping-administrator-Jitter] destination-port 9000
# Configure to make 10 probes per test.
[Sysname-hwping-administrator-http] count 10
# Set the probe timeout time to 30 seconds.
[Sysname-hwping-administrator-Jitter] timeout 30
# Start the test.
[Sysname-hwping-administrator-Jitter] test-enable
# Display test results
[Sysname-hwping-administrator-Jitter] display hwping results administrator Jitter
HWPing entry(admin administrator, tag Jitter) test result:
Destination ip address:10.2.2.2
Send operation times: 100
Min/Max/Average Round Trip Time: 9/21/13
Square-Sum of Round Trip Time: 18623
Last complete test time: 2000-4-2 8:14:58.2
Extend result:
Receive response times: 100