H3C S5100-SI/EI Series Ethernet Switches
Installation Manual
Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Manual Version: 20080123-C-1.05

Advertisement

Table of Contents
loading

Summary of Contents for H3C H3C S5100-SI Series

  • Page 1 H3C S5100-SI/EI Series Ethernet Switches Installation Manual Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Manual Version: 20080123-C-1.05...
  • Page 2 Copyright © 2007-2008, Hangzhou H3C Technologies Co., Ltd. and its licensors All Rights Reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co., Ltd.
  • Page 3: About This Manual

    About This Manual Related Documentation In addition to this manual, each H3C S5100-SI/EI Series Ethernet Switches documentation set includes the following: Manual Description H3C S5100-SI/EI Series Ethernet It is used for assisting the users in data Switches Operation Manual configurations and typical applications.
  • Page 4 Conventions The manual uses the following conventions: I. GUI conventions Convention Description Button names are inside angle brackets. For example, click < > <OK>. Window names, menu items, data table and field names are inside square brackets. For example, pop up the [New User] window.
  • Page 5: Table Of Contents

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Table of Contents Table of Contents Chapter 1 Product Overview ......................1-1 1.1 Preface..........................1-1 1.2 S5100-SI Series Ethernet Switches................... 1-2 1.2.1 S5100-8P-SI Ethernet Switch ................. 1-2 1.2.2 S5100-16P-SI Ethernet Switch ................1-4 1.2.3 S5100-24P-SI Ethernet Switch ................
  • Page 6 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Table of Contents 2.2.2 Cleanness ....................... 2-2 2.2.3 Electromagnetic Susceptibility ................2-2 2.2.4 Safety in Use of Laser..................... 2-3 2.3 Installation Tools ........................ 2-3 Chapter 3 Installing the Switch ....................3-1 3.1 Rack-Mounting the Switch ....................3-1 3.1.1 Introduction to Mounting Ear ...................
  • Page 7 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Table of Contents 5.2 Local Software Loading ..................... 5-1 5.2.1 Boot Menu ....................... 5-2 5.2.2 Loading Software Using XModem Through Console Port ........5-3 5.2.3 Loading Software Using TFTP through Ethernet Port ..........5-8 5.2.4 Loading Software Using FTP Through Ethernet Port ..........
  • Page 8: Chapter 1 Product Overview

    H3C S5100 Series Ethernet Switches (hereinafter referred to as the H3C S5100 series) are Gigabit Ethernet switching products developed by H3C Technology Co., Ltd. The H3C S5100 series provide a variety of service features. The H3C S5100 series are designed as convergence and access devices for intranets and metropolitan area networks (MANs), and can also be used for connecting data center server clusters.
  • Page 9: S5100-Si Series Ethernet Switches

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview a time. Table 1-2 shows the mapping relations between the ports forming the Combo port. Table 1-2 Mapping relations between the ports forming the Combo port 10/100/1000Base-T Model 1000Base-X SFP port...
  • Page 10 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview (1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): 1000Base-X SFP port status LED (3): Console port (4): 7-segment digitron display (5): Power LED (6): Ethernet port mode switching LED...
  • Page 11: S5100-16P-Si Ethernet Switch

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview (1): Lock hole for theft prevention Figure 1-3 Lock hole for theft prevention on the back of the left side panel Note: The lock hole cannot be used when the screw hole above it is in use.
  • Page 12 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview (1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): 1000Base-X SFP port status LED (3): Console port (4): 7-segment digitron display (5): Power LED (6): Ethernet port mode switching LED...
  • Page 13: S5100-24P-Si Ethernet Switch

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview V. Cooling system An S5100-16P-SI Ethernet switch provides one fan for heat dissipation. 1.2.3 S5100-24P-SI Ethernet Switch I. Front panel An S5100-24P-SI Ethernet switch provides 24 x 10/100/1000Base-T autosensing Ethernet ports, four 1000Base-X SFP ports, and one console port on the front panel.
  • Page 14: S5100-48P-Si Ethernet Switch

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview IV. Cooling system An S5100-24P-SI Ethernet switch provides one fan for heat dissipation. 1.2.4 S5100-48P-SI Ethernet Switch I. Front panel An S5100-48P-SI Ethernet switch provides 48 x 10/100/1000Base-TX autosensing Ethernet ports, four 1000Base-X SFP ports, and one console port.
  • Page 15: S5100-Ei Series Ethernet Switches

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview IV. Cooling system An S5100-48P-SI Ethernet switch provides two fans for heat dissipation. 1.3 S5100-EI Series Ethernet Switches 1.3.1 S5100-8P-EI Ethernet Switch I. Front panel An S5100-8P-EI Ethernet switch provides 8 x 10/100/1000Base-T autosensing Ethernet ports, two 1000Base-X SFP ports, and one console port on the front panel.
  • Page 16: S5100-16P-Ei Ethernet Switch

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview The lock hole is on the back of the left side panel, as shown in Figure 1-3. Note: The lock hole cannot be used when the screw hole above it is in use.
  • Page 17: S5100-24P-Ei Ethernet Switch

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview II. Rear panel (1): AC power input (2): Grounding terminal Figure 1-13 Rear panel of an S5100-16P-EI Ethernet switch III. Side panel An S5100-16P-EI Ethernet switch provides a lock hole for locking the switch to a secure object for theft prevention.
  • Page 18: S5100-24P-Ei Ethernet Switch

    Alternatively, you can use either the AC power input alone or the DC power input alone. Make sure you use an RPS module recommended by H3C as the DC power input. AC input: Rated voltage range: 100 VAC to 240 VAC;...
  • Page 19: S5100-48P-Ei Ethernet Switch

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview Note: For the description of RPS and the auxiliary cables, see RPS500-A3 User Manual and RPS1000-A3 User Manual. IV. Cooling system An S5100-24P-EI Ethernet switch provides one fan for heat dissipation.
  • Page 20: S5100-26C-Ei Ethernet Switch

    Alternatively, you can use either the AC power input alone or the DC power input alone. Make sure you use an RPS module recommended by H3C as the DC power input. AC input: Rated voltage range: 100 VAC to 240 VAC;...
  • Page 21: S5100-26C-Ei Ethernet Switch

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview (1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): 1000Base-X SFP port status LED (3): Console port (4): 7-segment digitron display (5): Power LED (6): DC power LED (7): 10 G interface slot 1 LED...
  • Page 22: S5100-50C-Ei Ethernet Switch

    Chapter 1 Product Overview Alternatively, you can use either the AC power input alone or the DC power input alone. Make sure you use an RPS module recommended by H3C as the DC power input. AC input: Rated voltage range: 100 VAC to 240 VAC; 50 Hz or 60 Hz Max voltage range: 90 VAC to 264 VAC;...
  • Page 23: S5100-8P-Pwr-Ei Ethernet Switch

    Alternatively, you can use either the AC power input alone or the DC power input alone. Make sure you use an RPS module recommended by H3C as the DC power input. AC input: Rated voltage range: 100 VAC to 240 VAC;...
  • Page 24: S5100-8P-Pwr-Ei Ethernet Switch

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview (1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): 1000Base-X SFP port status LED (3): Console port (4): 7-segment digitron display (5): Power LED (6): Ethernet port mode switching LED...
  • Page 25: S5100-16P-Pwr-Ei Ethernet Switch

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview V. PoE S5100-8P-PWR-EI Ethernet switches support Power Over Ethernet (PoE). They can be connected to remote powered devices (PDs), such as IP phones, WLAN APs, Security and Bluetooth APs, over twisted pair cables to remotely supply -48 VDC power to the connected PDs.
  • Page 26 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview II. Rear panel (1): AC power input (2): Grounding terminal Figure 1-25 Rear panel of an S5100-16P-PWR-EI Ethernet switch III. Side panel An S5100-16P-PWR-EI Ethernet switch provides a lock hole for locking the switch to a secure object for theft prevention.
  • Page 27: S5100-26C-Pwr-Ei Ethernet Switch

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview VI. Cooling system An S5100-16P-PWR-EI Ethernet switch provides three fans for heat dissipation. 1.3.9 S5100-26C-PWR-EI Ethernet Switch I. Front panel An S5100-26C-PWR-EI Ethernet switch provides 24 x 10/100/1000Base-T autosensing Ethernet ports, four 1000Base-X SFP ports, and one console port on the front panel.
  • Page 28: S5100-50C-Pwr-Ei Ethernet Switch

    AC/DC power inputs can be used at the same time, acting as backup for each other. Alternatively, you can use either the AC power input alone or the DC power input alone. Make sure you use an RPS module recommended by H3C as the DC power input. AC input: Rated voltage range: 100 VAC to 240 VAC;...
  • Page 29: S5100-50C-Pwr-Ei Ethernet Switch

    Alternatively, you can use either the AC power input alone or the DC power input alone. If DC power input is used, make sure you use an RPS module recommended by H3C as the DC power input and use an external PoE module recommended by H3C as the DC power supply.
  • Page 30: Leds

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview Voltage range: -52 VDC to -55 VDC IV. PoE S5100-50C-PWR-EI Ethernet switches support PoE. They can be connected to remote PDs, such as IP phones, WLAN APs, Security and Bluetooth APs, over twisted pair cables to remotely supply -48 VDC power to the connected PDs.
  • Page 31: Dc Power Supply Led (Rps)

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview Table 1-3 Description of the power LED Mark Status Description Yellow, ON The switch is starting. Green, ON The switch has been normally started. The system is performing POST...
  • Page 32: Gigabit Autosensing Ethernet Port Status Leds

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview Table 1-5 Description of the mode LED Mark Status Description Invalid Green, ON The port LED is indicating rate mode. Mode LED Mode Yellow, ON The port LED is indicating duplex mode.
  • Page 33: Gigabit Sfp Port Status Led

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview Port mode LED status Description Power supply is normal. The power required exceeds the Green maximum output power of the port Blinking (3 Hz) or the available power of the switch is insufficient.
  • Page 34: Module Led

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview Table 1-7 Description of the Gigabit SFP port status LED Status Description The port is connected at 1,000 Mbps. Green Blinking (30 The port is receiving or sending data at 1,000 Mbps.
  • Page 35: 7-Segment Digitron Display

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview Table 1-8 Description of the module LED Mark Status Description The module has not been installed or connected. module been Green, ON installed and connected. MOD1 (or Module LED...
  • Page 36 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview Table 1-9 Description of the 7-segment digitron display Device PWR LED Mark Description status status The POST ID of the in-process test is POST Green, displayed. running blinking The POST ID of the failed test blinks.
  • Page 37: System Features Of The S5100 Series

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview 1.5 System Features of the S5100 Series 1.5.1 System Features of the S5100-SI Series Table 1-10 System features of the S5100-SI series S5100-24P- Item S5100-8P-SI S5100-16P-SI S5100-48P-SI Dimension 43.6 × 230 × 200 43.6 ×...
  • Page 38: System Features Of The S5100-Ei Series

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview 1.5.2 System Features of the S5100-EI Series Table 1-11 System features of the S5100-EI series (1) S5100-24P-E S5100-48P-E Item S5100-8P-EI S5100-16P-EI 43.6 × 230 × 43.6 × 300 ×...
  • Page 39 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview Item S5100-26C-EI S5100-50C-EI × 10/100/1000MBase-T × 10/100/1000MBase-T autosensing Ethernet ports autosensing Ethernet ports Service ports 4 Gigabit SFP Combo ports 4 Gigabit SFP Combo ports Extension Two 10 G slots...
  • Page 40 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview S5100-8P-P S5100-16P- S5100-26C-PW S5100-50C-PW Item WR-EI PWR-EI R-EI R-EI × × 10/100/1000 10/100/1000 × × Base-T Base-T 10/100/1000 10/100/1000Bas autosensing autosensing Base-T e-T autosensing Ethernet Ethernet autosensing Service ports...
  • Page 41: Ordering Sfp/Xfp/Xenpak Interface Modules

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview S5100-8P-PWR-EI, S5100-16P-PWR-EI, S5100-26C-PWR-EI, S5100-50C-PWR-EI Ethernet switches provide over-temperature protection. With this mechanism, the switch disables the PoE feature on all its ports for self-protection when its internal temperature exceeds the PoE protection temperature, and restores the PoE feature on all its ports when its internal temperature drops below the PoE restoration temperature.
  • Page 42: Ordering 10 G Stack Interface Modules

    XFP-LX-SM1310 XFP-LH40-SM1550-F1 XENPAK-SX-MM850 XENPAK optical modules XENPAK-LX-SM1310 XENPAK-LH40-SM1550 Note: You are recommended to use H3C's optical modules for the S5100-SI/EI series Ethernet switches. Only S5100-26C-EI, S5100-50C-EI, S5100-26C-PWR-EI, S5100-50C-PWR-EI switches support XFP optical modules, but these switches do not support the XFP modules that require -5.2 V power supply.
  • Page 43: Ordering Stack Cables

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview 1.8 Ordering Stack Cables Table 1-17 Ordering information for stack cables Model No. Length Description LS5M2STK1 50 cm (19.7 in.) CX4 stack cable (50 cm) LS5M2STK2 100 cm (39.4 in.) CX4 stack cable (1.0 m)
  • Page 44: Chapter 2 Preparing For Installation

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 2 Preparing for Installation Chapter 2 Preparing for Installation 2.1 Safety Precautions To avoid any device impairment or bodily injury caused by improper use, observe these rules: Before cleaning the switch, unplug the power plug from the switch first. Do not clean the switch with wet cloth or liquid.
  • Page 45: Cleanness

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 2 Preparing for Installation High temperature is the most undesirable condition, because it accelerates aging of insulation materials and can thus significantly lower reliability and service life of your switch. For the detailed temperature/humidity requirements for the products, see section 1.5 System Features of the S5100 Series.
  • Page 46: Safety In Use Of Laser

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 2 Preparing for Installation and leads (power cords, signaling cables and output wires). To eliminate the interferences, ensure the following: For the AC power supply that adopts TN system, use a single-phase three-wire power socket with Protection Earth (PE) to effectively filter interference from the power grid.
  • Page 47: Chapter 3 Installing The Switch

    Otherwise, you will bear any consequence resulted from your actions without permission. 3.1 Rack-Mounting the Switch You can mount an H3C S5100 switch into a 19-inch standard rack in one of the following four ways: Use front mounting ears...
  • Page 48: Introduction To Mounting Ear

    When the depth of a switch is greater than 300 mm (11.8 in.), the front mounting ears only secure the switch rather than bear its weight. Guide rails purchased from H3C apply only to standard racks 1,000 mm (39.4 in.) deep. Use other supports to substitute for guide rails in the case of other rack depths.
  • Page 49: S5100-48P-Ei 50

    (1) Screw hole used to fix the mounting ear to the rack (Use one M6 screw) Figure 3-2 Appearance of a rear mounting ear When you install an H3C S5100 series switch into a 19-inch standard rack, you should select front mounting ears with a proper length (L1 as shown in Figure 3-1) according to the physical dimensions of the switch.
  • Page 50: Introduction To Guide Rail

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch 3.1.2 Introduction to Guide Rail Figure 3-3 shows the appearance of a guide rail. Slotted hole 1: Used to fix the guide rail to the rear bracket. You can adjust the screw hole position according to the position of the switch.
  • Page 51: Use Front Mounting Ears And A Tray

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch Figure 3-4 Fix front mounting ears Place the switch horizontally in a proper position, and fix the other end of mounting ears to the front brackets with screws and captive nuts, as shown in Figure 3-5.
  • Page 52: Use Front And Rear Mounting Ears

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch 3.1.5 Use Front and Rear Mounting Ears Follow these steps to install a switch into a 19-inch standard rack with front and rear mounting ears: Wear an ESD-preventive wrist strap to check the grounding and stability of the rack.
  • Page 53 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch Figure 3-7 Fix rear mounting ears Hold the bottom of the switch with one hand and the front part of the switch with the other hand, and pull the switch into the cabinet gently, as shown in Figure 3-8.
  • Page 54 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch Screw 1: Load-bearing screw Figure 3-9 Effect diagram of front and rear mounting ear installation (1) Fix the other end of the front mounting ears to the front brackets with screws and captive nuts and ensure that front and rear mounting ears have fixed the switch in the cabinet securely, as shown in Figure 3-10.
  • Page 55: Use Front Mounting Ears And Guide Rails

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch Screw 1: Load-bearing screw Figure 3-10 Effect diagram of front and rear mounting ear installation (2) 3.1.6 Use Front Mounting Ears and Guide Rails Follow these steps to install a switch into a 19-inch standard rack with front mounting...
  • Page 56 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch Figure 3-11 Fix front mounting ears Install guide rails on the brackets on both sides of the cabinet with M5 self-tapping screws, as shown in Figure 3-12. Figure 3-12 Install guide rails Hold the two sides of the switch and slide it gently along the guide rails into the cabinet until it is located in a proper position, as shown in Figure 3-13.
  • Page 57 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch Figure 3-13 Install front mounting ears and guide rails Fix the other end of front mounting ears to the front brackets of the cabinet with M6 screws and captive nuts and ensure that the front mounting ears and guide rails have fixed the switch in the cabinet securely, as shown in Figure 3-14.
  • Page 58: Desk Mounting

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch 3.2 Desk Mounting When no 19-inch standard rack is available, you can simply place the switch on a clean desk. When doing so, you should ensure that: The desk is stable and well grounded.
  • Page 59: Magnet Mounting

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch As shown in Figure 3-17, drill two holes having a diameter of 5 mm (0.2 in.) in the wall on the same horizontal line, with a distance of 170 mm (6.7 in).
  • Page 60 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch I. Introduction to magnetic accessories A set of magnetic mounting accessories consists of one permanent magnets and one M3*6 countersunk head screws, as shown in Figure 3-18. Four sets of magnetic mounting accessories are needed for each S5100 switch.
  • Page 61 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch (1) Blind nut in the dent of the switch bottom (2) Permanent magnet (3) M3*6 countersunk head screw Figure 3-19 Magnet mounting Caution: Apply magnet mounting to only the above four models. Otherwise, a falloff or mis-operation may occur.
  • Page 62: Connecting Power Cord And Grounding Wire

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch 3.5 Connecting Power Cord and Grounding Wire 3.5.1 Connecting AC Power Cord I. AC power socket (recommended) You are recommended to use a mono-phase three-wire power socket with a neutral point or a multi-function power socket for computers.
  • Page 63: Connecting Dc Power Cord

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch Note: The AC power cord tie can prevent the AC power cord from accidentally falling off. Check whether the PWR LED on the front panel of the switch is ON. If yes, the power is properly connected.
  • Page 64 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch As shown in Figure 3-23, pass the two power cords through the air filter, insert them into the corresponding holes, and tighten them with screw 1 and screw 2.
  • Page 65: Connecting Grounding Wire

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch 3.5.3 Connecting Grounding Wire Caution: You should properly connect the switch grounding wire since it is crucial to the lightning protection and electromagnetic shield (EMS) of your switch.
  • Page 66 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch (1) Power input (2) Grounding screw (3) Protection grounding wire (4) Earth (5) Angle steel Figure 3-26 Ground the switch by burying the grounding body into the earth For an AC-powered switch, if none of the above two conditions is available, ground it through the PE wire of the AC power supply.
  • Page 67: Connecting Console Cable

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch For a DC-powered switch (–48 VDC), if none of the first two conditions is available, ground it through the return wire (RTN) of the DC power supply. In this case, make sure this RTN wire is well connected to the ground at the DC output of the DC power cabinet.
  • Page 68: Connecting Console Cable

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch Table 3-4 Console cable connector pinouts and mapping relation RJ-45 Signal Direction DB-9 ← ← ← → — → → → 3.6.2 Connecting Console Cable Follow these steps to connect a terminal device, a PC for example, to the switch: Step 1: Connect the DB-9 female connector of the Console cable to the serial port of the PC or the terminal device used to configure the switch.
  • Page 69: Installing And Removing Optional Interface Modules

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch 3.7 Installing and Removing Optional Interface Modules 3.7.1 XFP Interface Module I. Appearance and front panel Figure 3-30 Appearance of an XFP interface module Figure 3-31 Front panel of an XFP interface module II.
  • Page 70 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch (1): Switch (2): Optional module slot (3): XFP interface module (4): Push-in direction Figure 3-32 Installing an XFP interface module Step 4: Tighten the fastening screws with a screwdriver to fix the XFP interface module.
  • Page 71: Stack Module

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch Caution: When installing or removing an optional interface module, pay attention to the following points: Do not use too much force in the operation, and do not touch the surface-mounted components directly with your hands.
  • Page 72: Xenpak Optical Module

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch 3.7.3 XENPAK Optical Module I. Appearance and front panel Figure 3-35 Appearance of an XENPAK optical module Figure 3-36 Front panel of an XENPAK optical module II. Installation Step 1: Put on an ESD-preventive wrist strap and verify the ESD-preventive wrist strap properly grounded.
  • Page 73 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch (1): Switch (2): Filler panels for optional module slots (3): Small cover plate (removed) in the middle on the filler panel (4): Push-in direction (5): XENPAK optical module...
  • Page 74: Installing And Removing Dedicated Stack Cables

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch 3.8 Installing and Removing Dedicated Stack Cables 3.8.1 Introduction In a stack of the S5100-EI series switches, dedicated stack cables are needed to connect the 10GE stack ports of the switches.
  • Page 75: Verifying The Installation

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch Caution: The dedicated stack cables for the S5100-EI series are hot-swappable. When tightening the fastening screws at both sides of the stack cable plugs using a flathead screwdriver or an electric screwdriver, make sure that the torque is not bigger than 0.4N•m.
  • Page 76: Chapter 4 Powering On The Switch For The First Time

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 4 Powering on the Switch for the First Time Chapter 4 Powering on the Switch for the First Time 4.1 Set up the Configuration Environment Set up the configuration environment as shown in Figure 4-1: Connect a terminal, a PC in this example, to the console port on the switch with a console cable.
  • Page 77 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 4 Powering on the Switch for the First Time Parameter requirements: Set “Bits per second” to 9600, “Data bits” to 8, “Parity” to “none”, “Stop bits” to 1 and “Flow control” to “none”. Select VT100 as terminal emulation.
  • Page 78 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 4 Powering on the Switch for the First Time Click <OK> after selecting a serial port and the system pops up the following interface. On the interface, set “Bits per second” to 9600, “Data bits” to 8, “Parity”...
  • Page 79: Booting The Switch

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 4 Powering on the Switch for the First Time Choose [Properties] in the HyperTerminal dialog box to enter the properties window. Click [Settings] to enter the following properties setting window, select VT100 as the terminal emulation, and then click <OK>.
  • Page 80 Chapter 4 Powering on the Switch for the First Time Starting..*********************************************************** H3C S5100-48P-EI BOOTROM, Version 616 *********************************************************** Copyright(c) 2004-2007 Hangzhou H3C Technologies Co., Ltd. Creation date : Apr 16 2007, 11:29:53 CPU Clock Speed : 200MHz BUS Clock Speed : 33MHz...
  • Page 81: Changing The Startup Mode

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 4 Powering on the Switch for the First Time 0. Reboot Enter your choice(0-9): If you perform no operation or press a key other than <Ctrl + B> within two seconds, once the remaining waiting time becomes zero, the system begins to automatically start up and the following information is displayed: Auto-booting...
  • Page 82 Enter 0. The system reboots in normal mode and displays the following information: Starting..*********************************************************** H3C S5100-48P-EI BOOTROM, Version 616 *********************************************************** Copyright(c) 2004-2007 Hangzhou H3C Technologies Co., Ltd. Creation date : Apr 16 2007, 11:29:53 CPU Clock Speed : 200MHz BUS Clock Speed : 33MHz...
  • Page 83 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 4 Powering on the Switch for the First Time key other than <Ctrl + B> within five seconds, the system begins to automatically start up and the following information is displayed: Auto-booting...
  • Page 84 Chapter 4 Powering on the Switch for the First Time Note: The H3C Series Switches provides abundant command views. For detailed descriptions about the configuration commands and CLI, refer to H3C S5100 Series Ethernet Switches Operation Manual and H3C S5100 Series Ethernet Switches...
  • Page 85: Chapter 5 Boot Rom And Host Software Loading

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading Chapter 5 Boot ROM and Host Software Loading Traditionally, the loading of switch software is accomplished through the serial port. This approach is slow, inconvenient, and cannot be used for remote real-time loading.
  • Page 86: Boot Menu

    Boot ROM loading process. 5.2.1 Boot Menu Starting..*********************************************************** H3C S5100-48P-EI BOOTROM, Version 616 *********************************************************** Copyright(c) 2004-2007 Hangzhou H3C Technologies Co., Ltd. Creation date : Apr 16 2007, 11:29:53 CPU type : BCM5836 CPU Clock Speed : 200MHz...
  • Page 87: Loading Software Using Xmodem Through Console Port

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading Input the correct Boot ROM password (by default, no password is set on the switch). The system enters the Boot Menu: BOOT MENU 1. Download application file to flash 2.
  • Page 88 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading Enter your choice(0-3): Step 2: Enter 3 in the above menu to load the Boot ROM software using XModem. The system displays the following download baud rate setting menu: Please select your download baudrate: 1.* 9600...
  • Page 89 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading Figure 5-1 Properties dialog box Figure 5-2 Console port configuration dialog box Step 5: After setting the baud rate, you need to disconnect and the reconnect...
  • Page 90 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading to disconnect the HyperTerminal from the switch and then click the <Call> button to reconnect the HyperTerminal to the switch. Figure 5-3 Call and disconnect buttons...
  • Page 91 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading Figure 5-5 Send file page Step 9: After the download completes, the system displays the following information: Loading ...CCCCCCCCCC done! Note: You do not need to reset the HyperTerminal’s baud rate and can skip the last step if you have chosen 9600 bps.
  • Page 92: Loading Software Using Tftp Through Ethernet Port

    Caution: TFTP server program is not provided with the H3C Series Switches. Step 3: Run the terminal emulation program on the configuration PC. Start the switch. Then enter the Boot Menu. At the prompt "Enter your choice(0-9):" select 6 in the Boot Menu and then press <Enter>...
  • Page 93: Loading Software Using Ftp Through Ethernet Port

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading 2. Set FTP protocol parameter 3. Set XMODEM protocol parameter 0. Return to boot menu Enter your choice(0-3): Step 4: Select 1 to download the Boot ROM software using TFTP. Then set the...
  • Page 94 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading II. Loading Boot ROM software Switch Switch Console port Console port Ethernet port Ethernet port Server Server FTP Client FTP Client FTP Server FTP Server...
  • Page 95: Remote Software Loading

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading Step 6: Enter Y to start file downloading or N to return to the Boot ROM update menu. If you enter Y, the system begins to download and update the program. Upon completion, the system displays the following information: Loading........done...
  • Page 96 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading <H3C> ftp 10.1.1.1 Trying ... Press CTRL+K to abort Connected. 220 WFTPD 2.0 service (by Texas Imperial Software) ready for new user User(none):abc 331 Give me your password, please...
  • Page 97: Remote Loading Using Tftp

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading 5.3.2 Remote Loading Using TFTP The remote loading by using TFTP is similar to the remote loading by using FTP. The only difference is that it is TFTP that you use when loading software to the switch. In this case, the switch can only be used as a TFTP client.
  • Page 98: Chapter 6 Maintenance And Troubleshooting

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 6 Maintenance and Troubleshooting Chapter 6 Maintenance and Troubleshooting 6.1 Software Loading Failure If software loading fails, the system keeps running in original version. In this case, check if the physical ports are properly connected: If the ports are not properly connected, reconnect them correctly and restart the loading procedure.
  • Page 99: Missing Boot Rom Password

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 6 Maintenance and Troubleshooting Select 7, and then restart the switch. After the switch is restarted, the configuration file will be skipped. 6.2.2 Missing Boot ROM Password Please contact your switch dealer.
  • Page 100 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Table of Contents Table of Contents Appendix A Lightning Protection of the Switch.................A-1 A.1 Installation of Lightning Arrester for AC Power (Socket Strip with Lightning Protection)..A-1 A.2 Installation of Lightning Arrester for Network Port.............A-2...
  • Page 101: Appendix A Lightning Protection Of The Switch

    Installation Manual H3C S5100-SI/EI Series Ethernet Switches Appendix A Lightning Protection of the Switch Appendix A Lightning Protection of the Switch A.1 Installation of Lightning Arrester for AC Power (Socket Strip with Lightning Protection) Caution: Lightning arrester will not be shipped with the switch. You should purchase it by yourself if needed.
  • Page 102 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Appendix A Lightning Protection of the Switch Caution: Make sure that the arrester is well grounded before using the lightning arrester for power. After inserting AC power cord plug of switch into the socket of lightning arrester, if the green LED is on and the red LED does not alarm, it means that the lightning arrester of power is running and the function of lightning protection has taken effect.
  • Page 103 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Appendix A Lightning Protection of the Switch Multimeter Tilted wire cutter II. Installation procedure Step 1: Tear the protection paper at one side of the double faced adhesive tape apart from the tape, and stick the tape on the surface of the arrester. Tear the protection paper at another side apart from the tape, and stick the arrester onto the chassis of the switch.
  • Page 104 Installation Manual H3C S5100-SI/EI Series Ethernet Switches Appendix A Lightning Protection of the Switch III. Installation precautions Fully consider the following items in the installation process, otherwise, the performance of the lightning arrester for network port will be affected: Lightning arrester for network port is installed in reverse direction. In practice, the “IN”...

Table of Contents