To do...
Configure the test type
Configure the number
of probes per test
Configure the
maximum number of
history records that can
be saved
Configure the
automatic test interval
Configure the probe
timeout time
Configure the type of
service
Configure the type of
FTP operation
Configure an FTP login
username
Configure an FTP login
password
Configure a file name
for the FTP operation
Start the test
Display test results
4)
Configuring HTTP test on HWPing client
Follow these steps to configure HTTP test on HWPing client:
To do...
Enter system view
Enable the HWPing
client function
Create a HWPing test
group and enter its view
Use the command...
test-type ftp
count times
history-records number
frequency interval
timeout time
tos value
ftp-operation { get | put }
username name
password password
filename file-name
test-enable
display hwping results
[ admin-name operation-tag ]
Use the command...
system-view
hwping-agent enable
hwping administrator-name
operation-tag
1-7
Remarks
Required
By default, the test type is ICMP.
Optional
By default, each test makes one probe.
Optional
By default, the maximum number is 50.
Optional
By default, the automatic test interval is
zero seconds, indicating no automatic
test will be made.
Optional
By default, a probe times out in three
seconds.
Optional
By default, the service type is zero.
Optional
By default, the type of FTP operation is
get, that is, the FTP operation will get a
file from the FTP server.
Required
By default, neither username nor
password is configured.
Required
By default, no file name is configured for
the FTP operation
Required
Required
You can execute the command in any
view.
Remarks
Required
By default, the HWPing client function is
disabled.
Required
By default, no test group is configured.