Displaying Hwping Configuration; Configuration Example - H3C S3600 Series Operation Manual

Hide thumbs Also See for S3600 Series:
Table of Contents

Advertisement

Operation Manual – HWPing
H3C S3600 Series Ethernet Switches-Release 1510
Configure the automatic
test interval.
Configure
time of the test.
Execute the test

1.2.3 Displaying HWPing Configuration

After the above HWPing configuration, you can execute the display command in any
view to display the information of HWPing test operation status to you can verify the
configuration effect.
Table 1-2 Display HWPing configuration
Display the information of
HWPing test history
Display the latest HWPing
test results

1.2.4 Configuration Example

I. Network requirement
Perform an HWPing ICMP test between two switches. Like a ping test, this test uses
ICMP to test the RTTs of data packets between the source and the destination.
II. Configuration procedure
# Enable HWPing Client.
<H3C> system-view
System View: return to User View with Ctrl+Z.
[H3C] hwping-agent enable
# Create an HWPing test group "administrator icmp".
[H3C] hwping administrator icmp
# Specify the test type as ICMP.
Operation
frequency interval
the
timeout
timeout time
test-enable
Operation
display hwping history
[
operation-tag ]
display hwping results
[
operation-tag ]
Chapter 1 HWPing Configuration
Command
Command
administrator-name
administrator-name
1-3
Description
Optional
By default, the automatic
test
interval
is
zero,
indicating no automatic
test will be performed.
Optional
By default, the timeout
time is 3 seconds.
Required
Description
The display command
can be executed in any
view.

Advertisement

Table of Contents
loading

Table of Contents