Fluke 9100 User Handbook Manual page 9

Universal calibration system
Hide thumbs Also See for 9100:
Table of Contents

Advertisement

6.2.2
9100 SCPI Subsystems
CALibration
Used to calibrate the functions and hardware ranges of the 9100, correcting for system errors which have
accumulated due to drift and ageing effects: ........................................................................................................................ 6-25
SECure
:PASSword. Gains access to Calibration operations, using 'Cal Enable' switch and Password.
:EXIT. Permits clean exit from calibration operation ..................................................................... 6-25
TARGet
Sets up the calibration target point, hardware range (and frequency, where required). ................ 6-26
TRIGger?
Initiates the calibration at a single point, once the target and levels have been set up,
and returns '0' for pass, and '1' for fail ............................................................................................ 6-27
SPECial?
Runs the DAC characterization and returns '0' for pass, and '1' for fail ......................................... 6-27
CJUNction?
Runs the reference thermocouple junction temperature measurement
and returns '0' for pass, and '1' for fail ............................................................................................ 6-27
OUTPut
Used to control parameters associated with output connections: ........................................................................................ 6-28
[STATe] (?)
Controls output on/off switching ..................................................................................................... 6-28
COMPensation (?)
Switches the output connections for 4-wire/2-wire in impedance functions ................................... 6-28
ISELection (?)
For Current outputs, selects between front panel terminals (High currents, Current coils), and
front panel D-type Socket (Low currents) ....................................................................................... 6-29
[SOURce]
Used to select the main 9100 Function (Voltage, Current etc.), to be output: ...................................................................... 6-30
FUNCtion
Selects the Waveshape of output signals ...................................................................................... 6-32
VOLTage
Selects the Voltage source for output ............................................................................................ 6-34
CURRent
Selects the Current source for output ............................................................................................ 6-36
RESistance
Selects the Resistance source for output ....................................................................................... 6-37
CONDuctance
Selects the Conductance source for output ................................................................................... 6-38
CAPacitance
Selects the Capacitance source for output .................................................................................... 6-39
FREQuency
Controls the Output Frequency value for AC functions .................................................................. 6-40
PHASe
Selects and controls the Phase-shifting facility .............................................................................. 6-41
PULSe
Selects and controls the Pulse source for output ........................................................................... 6-43
TEMPerature
Selects and controls the Temperature sources for output ............................................................. 6-44
STATus
Gives access to the 9100 SCPI-defined Status Reporting Structure: .................................................................................. 6-49
OPERation
Reads from, or writes to, the OPERation Status Register ............................................................. 6-49
QUEStionable
Reads from, or writes to, the QUEStionable Status Register ......................................................... 6-51
PRESet
Presets a default status reporting condition ................................................................................... 6-52
SYSTem
Collects general functions that are not related to 9100 performance: .................................................................................. 6-53
ERRor?
Requests the next entry from the 9100 error queue. ..................................................................... 6-53
DATE(?)
Reads or writes the present date ................................................................................................... 6-54
TIME(?)
Reads or writes the present time ................................................................................................... 6-55
SVOLtage(?)
Reads or writes the Safety Threshold Voltage in DC or AC Voltage function ................................ 6-56
VERSion?
Returns a numeric value corresponding to the SCPI version for which the instrument complies .. 6-56
Section 6: 9100 System Operation — SCPI Language
Final Width = 215mm
6-3