SCPI Command Set and Conformance Information
The SCPI Standard requires that certain information be supplied to the user about how the device has implemented the standard.
The Documentation Requirements are detailed in Section 4.2.3 of the Standard document Standard Commands for Programmable
Instruments SCPI 1994; Volume 1: Syntax and Style; on page 4-6. The following paragraphs comply with those requirements:
1.
The SCPI Version to which the Instrument Complies:
The instrument complies with the version 1994. The Confirmed Query: SYSTem:VERSion? will return this version number.
2.
Syntax of All SCPI Commands and Queries Implemented in the Model 9100
All the Commands and Queries are present, each annotated with the state of its SCPI approval.
Keyword
Parameter Form
CALibration<n>
:SECure
:PASSword
<SPD>
:EXIT
[<SPD>,<CPD>{PRD7|PRD14|PRD30|PRD60}] ..................................................................... Not SCPI Approved
:TARGet
<DNPD>,<DNPD>[,<DNPD>]
:TRIGger?
:SPECial?
:CJUNction?
<DNPD>
OUTPut<n>
[:STATe](?)
<CPD>{ON|OFF|0|1}
:COMPensation(?)
<CPD>{ON|OFF|0|1}
:ISELection(?)
<CPD>{HIGHi|HI50turn|HI10turn|LOWi} ............................................................................. Not SCPI Approved
[SOURce<n>]
:FUNCtion
[:SHAPe](?)
<CPD>{DC|SINusoid|PULSe|SQUare|IMPulse|TRIangle|TRAPezoid|SYMSquare} .............. Not SCPI Approved
:VOLTage
[:LEVEl]
[:IMMediate]
[:AMPLitude](?)
<DNPD>
:HIGH(?)
<DNPD>
:LOW(?)
<DNPD>
:CURRent
[:LEVEl]
[:IMMediate]
[:AMPLitude](?)
<DNPD>
Appendix B to Section 6: 9100 System Operation — SCPI Documentation Requirements
Notes
SCPI Approval
............................................................................. Confirmed
............................................................................. Not SCPI Approved
............................................................................. Not SCPI Approved
............................................................................. Not SCPI Approved
[query only] ......................................................... Not SCPI Approved
[query only] ......................................................... Not SCPI Approved
............................................................................. Not SCPI Approved
............................................................................. Confirmed
............................................................................. Confirmed
............................................................................. Not SCPI Approved
............................................................................. Confirmed
............................................................................. Confirmed
............................................................................. Confirmed
............................................................................. Confirmed
............................................................................. Confirmed
............................................................................. Confirmed
............................................................................. Confirmed
............................................................................. Confirmed
............................................................................. Confirmed
............................................................................. Confirmed
............................................................................. Confirmed
............................................................................. Confirmed
Appendix B to
Section 6 of the
User's Handbook for
Model 9100
Continued Overleaf
6-B1
Final Width = 215mm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents