Chapter 2 - Description and Installation
Terminating Cables at Station Locations
Terminate key telephones and DTMF single-line telephone cables on four conductor
modular jack assemblies at each station location. Four conductors provide two pair-wired
to the telephone. Although only one pair is required for key telephone operation, the
second pair is wired through to the ADP jack for a variety of applications at the desktop.
For exception, refer to
Cable Conductor
White/Blue
Blue/White
White/Orange
Orange/White
Do not mount the modular jack assemblies on the wall at this time. They will be wall
mounted later when the station instruments are installed.
Key Telephones Installation
Key telephones may be mounted with three different orientations: Low Profile Desk
Mount, High Profile Desk Mount or Wall Mounted. Packaged inside each key telephone
carton are the following components:
Key telephone
Key telephone handset
7-ft. line cord
4-in. line cord (for wall mounting)
12-ft. handset cord
Small base-wedge mount assembly
Large base-wedge mount assembly
Remove the components from the carton and determine which mounting components
are required. Most telephones are installed with both mounting wedges.
Table2-14
Table 2-14: Station Location Cable Terminations
Jack Wire Color
Since the digital station equipment is not polarity sensitive, reversing the digital telephone
pair has no affect on operation. The Station Interface circuits are current-limited and are
not fused.
The two wedge mount assemblies (large and small) are affixed at the factory. This
configuration is used for High Profile Desk Mounting.
.
Green
Telephone voice and data XT lead
Red
Telephone voice and data XR lead
Black
ADP Jack Tip lead
Yellow
ADP Jack Ring lead
DH S-L Instal lation
Designation