DHS- L Instal lation
Cautionary Steps
To reduce the risk of fire or injury to persons, read and follow these tips:
Use only the following type and size battery(ies) listed here as the maximum battery
type and size: 24vdc, 40 AH.
Do not dispose of any battery(ies) in a fire, the cell may explode. Check with local
codes for possible special disposal instructions.
Do not open or mutilate the battery(ies). Released electrolyte is corrosive and may
cause damage to the eyes or skin. It may be toxic if swallowed.
Exercise care in handling batteries in order not to short the battery with conducting
materials such as rings, bracelets, and keys. The battery or conductor may overheat
and cause burns.
Charge the battery(ies) provided with or identified for use with this product only in
accordance with the instructions and limitations specified in this manual.
Observe proper polarity orientation between the battery(ies) and battery charger.
Do not mix old and new batteries in this product (applies to products employing
more than one user replaceable secondary battery).
Do not mix batteries of different sizes or from different manufacturers in this product
(applies to products employing more than one user-replaceable, secondary battery).

KSU Installation

The KSU is designed for wall mounting only. The KSU should NOT be mounted directly on
a masonry surface. If the KSU is to be mounted on a masonry surface, a wooden
backboard of sufficient size should be attached to the wall and the KSU mounted on the
backboard.
1. Using the mounting template as a guide, mark the 2 mounting screws locations on
the MDF backboard.
2. Predrill 2 screw holes and install 2 pan-head No. 10 screws into the backboard. The
screw heads should protrude about 1/4-in. from the backboard plywood surface.
3. Lift the KSU over the 2 screws allowing the screws to extend into the KSU slotted
mounting holes. As the KSU is allowed to rest in place on the mounting screws it will
slip over the screw shanks until the top of the slot is reached. Properly installed, the
KSU power transformer (where the KSU AC power cord is located) is positioned in the
upper left corner. The power switch and Power/Heartbeat LED are positioned at the
left side of the KSU toward the bottom.
It is very important that the KSU be correctly mounted to allow proper power supply heat
dissipation.