2-Port Analog Adapter - STARPLUS DHS-L Technical Manual

Hide thumbs Also See for Starplus DHS-L:
Table of Contents

Advertisement

2-48
Chapter 2 - Description and Installation
3. Terminate the Loud Bell and power supply leads on an industry standard 66M1-50
block.
4. Using cross-connect (jumper) wire, connect each of the three LBC components
(contact, bell and power source) in series fashion.

2-Port Analog Adapter

The 2-Port Analog Adapter is used to connect analog SLTs and other analog devices to
the system. The analog device must provide DTMF (touch tone) signals in order to make
intercom calls, access outside lines and to activate system features. Some examples of
analog devices are: telephone answering device (TAD), facsimile machine (FAX) or
modem.
The 2-Port Analog Adapter is designed for installation at the MDF but may be positioned
anywhere along the cable path between the KSU and the SLT (or other analog device).
1. The 2-Port Analog Adapter is contained in a wall mount enclosure with pre-drilled
flanges for simple mounting. Properly mounted, the hinged cover will open upward
and lock into position for servicing.
2. Inside the enclosure, the 2-Port Analog Adapter Printed Circuit Board (PCB) is seen
with three RJ-11 modular jacks along the bottom edge of the PCB. One oriented
toward the right side of the 2-Port Analog Adapter PCB is labeled IN. The other two
jacks are labeled OUT1 and OUT2.
3. Extend each of these jacks to the MDF using modular cords and terminal blocks.
4. Once on the MDF, connect the IN jack to the desired digital station port to be used for
analog device interface. This connection requires that the green and red wires
(White/Blue pair) be used.
5. The modular jack OUT1 is now operational as an analog device port with the same
station number that would have been used by a digital key telephone connected to
this port. (The OUT2 is the same extension as if a DTIB-16 card was installed in the slot
or the B2 channel for that slot.)
The LBC output on the KSU provides only interrupteddrycontactclosure during theringing
period of incoming CO Lines.
Relay contacts on the DHS-L are rated at 50V DC 1.0 amp. Do notapply AC voltage to these
contacts.
The 2-Port Analog Adapter is not an OPX device as determined by FCC Rules. Additional
equipment is required to support OPX lines. The Analog Adapter will not support Message
Waiting Indication for SLT devices. The Analog Adapter will supply Stutter Dial Tone to the
user.
The 2-Port Analog Adapter only works with the DTIB-8.
Do not exceed the maximum cable length fromKSU to SLT regardless of where the 2-Port
CO Module is installed.