Dell PowerConnect B-FCXs Configuration Manual page 1456

Powerconnect b-series fcx
Hide thumbs Also See for PowerConnect B-FCXs:
Table of Contents

Advertisement

41
Syslog messages
TABLE 239
Message level
Notification
Warning
Warning
Warning
Warning
Warning
1414
Syslog messages (Continued)
Message
VRRP intf state changed,
intf <portnum>, vrid <virtual-router-id>,
state <vrrp-state>
DOT1X security violation at port <portnum>,
malicious mac address detected:
<mac-address>
Dup IP <ip-addr> detected, sent from MAC
<mac-addr> interface <portnum>
IGMP/MLD no hardware vidx, broadcast to
the entire vlan. rated limited number
IGMP/MLD: <vlanId>(<portId>) is V1 but
rcvd V2 from nbr <ipAddr>
Latched low RX Power | TX Power | TX Bias
Current | Supply Voltage | Temperature
warning
alarm | warning, port <port-number>
Explanation
A state change has occurred in a Virtual
Router Redundancy Protocol (VRRP)
interface.
The <portnum> is the port.
The <virtual-router-id> is the virtual router
ID (VRID) configured on the interface.
The <vrrp-state> can be one of the
following:
init
master
backup
unknown
A security violation was encountered at the
specified port number.
Indicates that the Dell PowerConnect device
received a packet from another device on
the network with an IP address that is also
configured on the Dell PowerConnect
device.
The <ip-addr> is the duplicate IP address.
The <mac-addr> is the MAC address of the
device with the duplicate IP address.
The <portnum> is the Dell PowerConnect
port that received the packet with the
duplicate IP address. The address is the
packet source IP address.
IGMP or MLD snooping has run out of
hardware application VLANs. There are
4096 application VLANs per device. Traffic
streams for snooping entries without an
application VLAN are switched to the entire
VLAN and to the CPU to be dropped. This
message is rate-limited to appear a
maximum of once every 10 minutes. The
rate-limited number shows the number on
non-printed warnings.
Port has received a query with a MLD
version that does not match the port MLD
version. This message is rated-limited to
appear a maximum of once every 10 hours.
The optical transceiver on the given port
has risen above or fallen below the alarm or
warning threshold.
PowerConnect B-Series FCX Configuration Guide
53-1002266-01

Advertisement

Table of Contents
loading

Table of Contents