Siemens MC55 Command Set page 436

Hide thumbs Also See for MC55:
Table of Contents

Advertisement

MC55 AT Command Set
17.5 AT^SCTM
Examples
EXAMPLE 1
URCs issued when the operating temperature is out of range:
^SCTM_A: 1
^SCTM_A: 2
^SCTM_B: 1
^SCTM_B: 2
^SCTM_A: -1
^SCTM_A: -2
^SCTM_B: -1
^SCTM_B: -2
EXAMPLE 2
URCs issued when the temperature is back to normal (URC is output once):
^SCTM_A: 0
^SCTM_B: 0
MC55_ATC_V01.05
Confidential / Released
Caution: Battery close to overtemperature limit.
Alert: Battery above overtemperature limit. Engine switches off.
Caution: Engine close to overtemperature limit.
Alert: Engine is above overtemperature limit and switches off.
Caution: Battery close to undertemperature limit.
Alert: Battery below undertemperature limit. Engine switches off.
Caution: Engine close to undertemperature limit.
Alert: Engine is below undertemperature limit and switches off.
Battery temperature back to normal temperature.
Engine back to normal temperature
Page 436 of 469