MC55 AT Command Set
2.13 AT^SCFG
Write Command
Configuration of URC "
^SLCC
AT^SCFG= "URC/CallStatus/SLCC"[,
Response(s)
^SCFG: "URC/CallStatus/SLCC",
Write Command
URC indication in datamode via RING line:
AT^SCFG= "URC/Datamode/Ringline"[,
Response(s)
^SCFG: "URC/Datamode/Ringline",
Write Command
URC indication via RING line:
AT^SCFG= "URC/Ringline"[,
Response(s)
^SCFG: "URC/Ringline",
Write Command
Duration of active RING line for URC indications:
AT^SCFG= "URC/Ringline/ActiveTime"[,
Response(s)
^SCFG: "URC/Ringline/ActiveTime",
PIN
ASC0
ASC1
MUX1
!
%
%
Reference(s)
SIEMENS
Command Description
The read command returns a list of all supported parameters with their current values.
The write command allows to query a configuration parameter (no value was given) or to set its value(s).
The following error codes are used:
"+CME ERROR: operation temporary not allowed" ... change of parameter value(s) temporarily not allowed
"+CME ERROR: invalid index" ... invalid parameter name or invalid value(s).
"+CME ERROR: invalid characters in text string" ... a character set conversion of parameter value(s) failed
"+CME ERROR: unknown" ... other errors