Scpi Command Quick Reference - HP E8402A User And Service Manual

Vxi c-size mainframe
Table of Contents

Advertisement

Keyword
:CALibration
[:ALL]?
:TEMPerature?
:VALue
:TEMPerature
:VOLTage
:VOLTage?
:DISPlay
[:WINDow]
:STATe
:TEXT[:DATA]
:FORMat:BORDer
:HISTory
:BLOWer
[:HISTogram]?
:CURRent
:CMAXimum?
[:HISTogram]?
:MAXimum?
:POWer
:CMAXimum?
[:HISTogram]?
:MAXimum?
:QUEue
:COUNt?
[:FETCh]?
:RESet
[:ALL]
:BLOWer
:CURRent
:POWer
:QUEue
:TEMPerature
:VOLTage
:TEMPerature
:CMAXimum?
:CMINimum?
[:HISTogram]?
:MAXimum?
:MINimum?
:TIME
:LCALibration?
:LHReset?
:LTST?
:ON?
:OPERating?
184 Programming the Enhanced Monitor

SCPI Command Quick Reference

Parameters
Notes
[query only] Performs complete calibration of the enhanced monitor.
[query only] Performs a calibration of the temperature monitoring function.
<value>
<supply>,<value>
<supply>
[query only] Performs a calibration of the voltage monitoring function.
<display window>
<state>
<string>
<order>
<blower>
[query only] Returns histogram data for the <blower>
<supply>
[query only] Returns <supply> maximum amperage since power-on.
<supply>
[query only] Returns <supply> amperage histogram data
<supply>
[query only] Returns the maximum amperage for the <supply>.
<supply>
[query only] Returns the maximum wattage since power-on for <supply>
<supply>
[query only] Returns <supply> wattage histogram data
<supply>
[query only] Returns the maximum wattage for the <supply>.
[query only] Returns the number of events in the history queue.
<event index>
[query only] Returns the queue for the <number> history event.
[no query]
<blower>
[no query]
<supply>
[no query]
<supply>
[no query]
[no query]
<slot>
[no query]
<supply>
[no query]
<slot>
[query only] Returns the maximum temperature since power-on in <slot>.
<slot>
[query only] Returns the minimum temperature since power-on in <slot>.
<slot>
[query only] Returns for histogram data on the <slot>
<slot>
[query only] Returns the maximum temperature in <slot>.
<slot>
[query only] Returns the minimum temperature in <slot>.
[query only] Returns hr, min, sec since last calibration.
[query only] Returns hr, min, sec since last history reset.
[query only] Returns hr, min, sec since last *TST.
[query only] Returns hr, min, sec since power-on.
[query only] Returns hr, min, sec mainframe has been operating.
Description
Sets/returns the calibration temperature.
Sets/returns the calibration voltage value for each VXI supply.
Set/returns display data screen to < display window >
Set/returns state of mainframe's display (ON|OFF|AUTO)
Displays a user-defined message on the display.
Sets/returns the byte order (NORM|SWAP)
Resets the data in the entire history subsystem to zero.
Resets the data in <blower> history to be zero.
Resets the data in <supply> amperage history to be zero.
Resets the data in <supply> wattage history to be zero.
Erases all the data in the history queue.
Resets the data in <slot> history to be zero.
Resets the data in <supply> voltage history to be zero.
Chapter 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

E8404a

Table of Contents