HP E8402A User And Service Manual page 183

Vxi c-size mainframe
Table of Contents

Advertisement

:UNIT[:TIME]
:VOLTage
:CMAXimum?
:CMINimum?
[:HISTogram]?
:MAXimum?
:MINimum?
:STATus
:OPERation
:CONDition?
:ENABle
[:EVENt?]
:PRESet
:QUEStionable
:BLOWer
:CONDition?
:ENABle
:[EVENt]?
:LEVel?
:SPEed?
:CONDition?
:CURRent
:CMAXimum?
:CONDition?
:ENABle
:[EVENt]?
:LEVel?
:LIMit
:MAXimum?
:ENABle
[:EVENt?]
:FILTer
:TINTerval
:TREMaining?
:TRESet
:POWer
:CMAXimum?
:LEVel?
:LIMit
:MAXimum?
:TEMPerature
:CMAXimum?
:CONDition?
:ENABle
:[EVENt]?
:LEVel?
:LIMit
:MAXimum?
:UMCounter
:TINTerval
Chapter 3
<unit>
<supply>
[query only] Returns the maximum voltage since power-on for <supply>
<supply>
[query only] Returns the minimum voltage since power-on for <supply>
<supply>
[query only] Returns <supply> voltage histogram data
<supply>
[query only] Returns the maximum voltage for the <supply>.
<supply>
[query only] Returns the minimum voltage for the <supply>.
[query only] Returns OPERation Condition Register.
<mask>
[query only] Returns Operation Event Register
[no query]
[query only] Returns the contents of the Blower condition register
<mask>
[query only] Returns the contents of the Blower event register
[query only] Returns the mainframe fans' percentage level.
<blower>
[query only] Returns the last fan RPM measurement
[query only] Returns Questionable Condition Register
<supply>
[query only] Alias for HIST:CURR:CMAX
[query only] Returns the contents of the Current Condition Register
<mask>
[query only] Returns the contents of the Current Event Register
<supply>
[query only] Returns the last power supply current measurement.
<supply>,<value>
<supply>
[query only] Alias for HIST:CURR:MAX
<mask>
[query only] QUEStionable status group events
<interval>
[query only] Alias for STAT:QUES:UMC:TREM?
<supply>
[query only] Alias for HIST:POW:CMAX
<supply>
[query only] Returns the last power supply power measurement.
<limit>
<supply>
[query only] Alias for HIST:POW:MAX
<slot>
[query only] Alias for HIST:TEMP:CMAX
[query only] Returns the contents of the Temperature condition register
<mask>
[query only] Returns the contents of the Temperature event register
<slot>
[query only] Returns the last <slot> temperature measurement.
<slot>,<val1>
[,<val2>[,<val3>]]
<slot>
[query only] Alias for HIST:TEMP:MAX
<time>
Sets/returns time units returned within the history subsystem.
Sets/returns Operation Enable Register
Clears OPER & QUES enable registers
Set/returns the Blower enable register
Sets/returns the Current Enable Register
Sets/returns maximum current limits.
Enable mask for QUEStionable status
Alias for STAT:QUES:UMC:TINT
Alias for STAT:QUES:UMC:TRES
Sets/returns maximum total power limit.
Sets/returnse Temperature enable register
Sets/returns maximum slot temperature limits.
Sets/returns the time interval.
Programming the Enhanced Monitor
185

Advertisement

Table of Contents
loading

This manual is also suitable for:

E8404a

Table of Contents