DME Designer Owner's Manual
Name
Gate Curve
Gain Reduction Meter
Output Meter
Parameter
Setting Range
Threshold
-54 dB to ±0 dB
Range
-70 dB to ±0 dB
Attack
0 to 120 ms
Hold
44.1 kHz: 0.02 ms to 2.13 s
48 kHz: 0.02 ms to 1.96 s
88.2 kHz: 0.01 ms to 1.06 s
96 kHz: 0.01 ms to 981 ms
Decay
44.1 kHz: 6 ms to 46 s
48 kHz: 5 ms to 42.3 s
88.2 kHz: 3 ms to 23 s
96 kHz: 3 ms to 21.1 s
KeyIn
Mono
Stereo
On
ON/OFF
+20
+10
0
–10
–20
–30
–40
–50
–60
–70
Displays results graphically. The horizontal axis is
the input signal level, and the vertical axis is the
output level.
Displays the gain reduction attenuation.
Displays the output signal level.
Sets the threshold value.
Sets the amount by which the level is reduced.
Sets the attack time.
Sets the hold time.
Sets the decay time.
The setting range may very, depending on the
operating frequency.
SELF
Selects the trigger source from a menu. The
KEYIN
currently selected trigger source is displayed on the
button.
L
R
LR BOTH
KEYIN
Turns the gate ON.
Threshold = –20dB
Range = –25dB
–70 –60 –50 –40 –30 –20 –10 0 +10 +20
Input Level (dB)
Function