Yamaha DME64N Owner's Manual page 141

Dme designer
Hide thumbs Also See for DME64N:
Table of Contents

Advertisement

4 [Remove User] Button
Deletes the user selected on the list. Only users at levels lower than the currently logged on user
can be deleted.
Furthermore, the currently logged on user cannot delete himself.
5 [Change] Button
Changes settings for the user selected on the list. Opens the "Change User Information" dialog
box. The contents of the dialog box are the same as the "Add User" dialog box.
6 Operation Security
Sets the functions that can be used by the user selected on the [User List] to the left. Selecting
a checkbox enables use of the corresponding function.
• [Edit]
You can change the following settings: editing in the Designer window, user control edit, user
defined parameter edit, word clock, scene edit, GPI and MIDI.
• [View DME Design Window]
Allows display of the Designer window.
• [Control Component Editor]
Allows parameter editing in the component editor.
• [View Component Editor]
Allows display of the component editor.
• [Change Configuration]
Allows switching between configurations.
• [Synchronization]
Allows synchronizing with the DME or SP2060 unit.
• [View Log Window]
Displays the "Event Logger" window.
• [Scene Store/Recall Level]
Sets the level at which scenes can be stored and recalled. Click the [ ] and [ ] buttons or
enter a number into the box to set the level. While levels 1 through 10 are available, the range
of levels that can be actually set varies according to the level of the user doing the setting.
When a user is created, automatically this is set to "One level lower than the user above." The
initially set level is the highest level that can be set for that user.
• [User Control Level]
Sets the user control level. Click the [ ] and [ ] buttons or enter a number into the box to set
a level from 1 through 10. While levels 1 through 10 are available, the range of levels that can
be actually set varies according to the level of the user doing the setting.
When a user is created, automatically this is set to "One level lower than the user above." The
initially set level is the highest level that can be set for that user.
7 [OK] Button
Applies any setting changes and closes the window.
8 [Cancel] Button
Closes the window without changing any settings.
Chapter 3 Main Panel Window
DME Designer Owner's Manual
141

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dme24nDme4io-cDme8i-cSp2060Dme8o-cDme designer 2.0

Table of Contents