Yamaha DME64N Owner's Manual page 104

Dme designer
Hide thumbs Also See for DME64N:
Table of Contents

Advertisement

Chapter 3 Main Panel Window
104
DME Designer Owner's Manual
• [Mute]
GPI input can be used to engage or disengage the DME mute function.
[Parameter], [Min], and [Max] are not available.
[Terminal] determines how the GPI input voltage will affect the specified parameter.
Mute will be ON when the voltage applied to GPI IN is above the median voltage*, and OFF when the
voltage is below the median.
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
Mute will be OFF when the voltage applied to GPI IN is above the median voltage*, and ON when the
voltage is below the median.
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
Mute will be alternately turned ON and OFF each time the voltage applied to GPI IN drops from
below to above the median voltage.*
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
Mute will be alternately turned ON and OFF each time the voltage applied to GPI IN rises from above
to below the median voltage.*
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
Mute ON
Median voltage
Mute OFF
Mute OFF
Mute OFF
Median voltage
Mute ON
Mute ON
ON
ON
Median voltage
OFF
ON
OFF
ON
Median voltage

Hide quick links: