Error Logs
Table 2-2 Continued
Error
Codes Description
8401
MISCELLANEOUS ERROR:
currently not reported.
8402
WINK TOO SHORT:
Outbound dialing problems on tie
trunks. For a tie trunk with delay dial or
wink start, the wink from the far end of
the network interface is less than the
minimum 100 ms. The tie trunk
remains waiting for a valid signal.
8403
NO EXTERNAL RELEASE:
Communication problems between
the module and central office. Far end translated properly, Troubleshoot for
has not disconnected within 4
minutes.
If this error occurs twice
consecutively, the trunk is busied-out
automatically, whether Automatic
Maintenance-Busy is enabled or not.
8404
ON HOOK BEFORE WINK:
Outbound dialing problems on tie
trunks, For a tie trunk with delay dial or
wink start, the far end of the network
interface went on-hook before the
handshake was completed.
Error Logs, Access Logs, and System Inventory 2-15
Action
action required.
N
O
Troubleshoot the far end of the network
interface to see if it is working and
translated properly. Troubleshoot for
faulty cable. Replace the module.
Troubleshoot the far end of the network
interface to see if it is working and
faulty cable.
If problem persists, troubleshoot the tie
trunk configuration. Troubleshoot the far
end to see if it is working and translated
properly. Troubleshoot for faulty cable.
Replace the module.