Module Problems
The screen below appears when the busy-out fails again; be sure to specify
the correct slot.
Console Display/Instructions
Busy-Out Slot xx:
Busy-out FAILED
Exit
Reset
Summary
Procedure
PC Procedure
Appropriate Modules
Time Estimate
To reset the module, follow the steps below.
1 From the Maintenance menu,
Maintenance
Make a selection
System
Slot
Port
Exit
4-40 Control Unit Problems
Additional Information
xx = slot number entered in
Menu → Maintenance → Slot → Dial the slot no.
→ Enter → Reset → Yes.
(F6) → (F2) → Type the slot no. → (F10) → (F7) → (F1)
Any module that you are about to test
Less than 1 second (all calls in progress are
terminated or put on hold immediately). If
you do not want to interrupt calls in progress,
use Busy-Out instead of Reset, as described
above.
select the
Slot option.
P C
Step
2
(F2)