Unit Load Calculation Worksheet
8. Calculate the unit loads for slots 5 and 6 of the carrier.
Equipment
Network Access Lines*
DS1
GS/LS
Tie
Telephones
MLX-10
MLX-10D
MLX-28D
MLX-20L
BIS-10
BIS-22
BIS-22D
BE-34
BIS-34D
MLC-5
MDC-9000
MDW-9000
10-Button Basic
10-Button HFAI
34-Button Basic
34-Button DLX
34-Button BIS
34-Button BIS/DIS
Single-Line Telephone
Continued
* Unit loads are computed per trunk for trunk-type network access lines.
Unit Load
Qty x
Hybrid/PBX or
Modiffied
Maintenance and Troubleshooting C–7
Square
0.0
0.0
0.0
0 . 0
1.4
1.4
0.9
1.2
0.9
1.2
1.2
1.7
1.1
1.6
0.9
1.1
1.0
1.3
1.0
1.3
1.1
1.5
1.1
1.5
0.0
0.0
0.0
0.0
0.0
0.0
0.9
1.1
1.0
1.2
0.9
1.1
1.2
1.7
1.2
1.4
1.2
1.4
0.6
0.7
= Total