Module Problems
If the test fails, find the error message in Table 4-3 and proceed as indicated.
Table 4-3. Internal Loopback Test Errors
Error Messages
Slot is not busied-out
Slot empty or not valid
FMWR not in Standby Mode
Test running too long
Not in TEST/STANDBY mode
Any other error
NOTE:
Be sure to check the second screen if testing a
MLX module.
Restoring the Module
When you are finished running module tests, restore the module. See
"Restore," earlier
Corrective Action
Exit the test, busy-out the slot, and try again.
Exit the test and try again; be sure to type the correct
slot number. Do not indicate an empty slot or the
processor (00).
Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
Record the errors on the repair tag and replace the
module.
chapter.
in this
module or a 408 GS/LS-
100D
Control Unit Problems 4-49