AT&T MERLIN LEGEND Release 3.0 Installation Manual page 439

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 3.0:
Table of Contents

Advertisement

Module Problems
Firmware on this circuit module can be upgraded or reinstalled with an
Upgrade memory card. An upgrade is performed when a new release of
firmware enhances a module's capabilities or corrects problems. Firmware
can be reinstalled if the existing circuit module firmware has been corrupted.
Summary
Console Procedure
PC Procedures
Appropriate Modules
Time Estimate
Busy-Out or Reset
Restore
Menu → Maintenance → Slot → Dial the slot
no. → Enter → Upgrade → Yes
(F6)
(F2)
Type the slot no.
(F10)
(F4)
This procedure can be run only on the 800
LS-ID module or modules introduced after
Release 3.0.
Approximately 1.5 minutes.
The module is automatically busied-out
after the upgrade procedure begins.
If Busy-Out is unsuccessful, you are given
the option of waiting for a Busy-Out or
selecting
Reset.
Restore the module after the upgrade
successfully completes.
Slot menu, which you can access by doing
the following from the console:
Menu → Maintenance → Slot
See "Restore," earlier in this chapter, for
additional information.
(F10)
(F8)
is in the
Restore
Control Unit Problems 4-61
or

Advertisement

Table of Contents
loading

Table of Contents