3Com 3C63400-3AC-C - PathBuilder S700 Switch Reference Manual page 223

Wan access switch
Table of Contents

Advertisement

Table 41 MCPU and STX Module (System) Alarms (continued)
Alarm
Meaning
New Card
Configuration data for a new
Configured
card is uploaded.
No Upload Image
Cannot find card image to
Found
upload. Bad code image. (STX)
PWR Supply 1
Power supply #1 is missing or
Absent
has failed.
PWR Supply 2
Power supply #2 is missing or
Absent
has failed.
PWR Supply 3
Power supply #3 is missing or
Absent
has failed.
PWR Supply 4
Power supply #4 is missing or
Absent
has failed.
PWR Supply 5
Power supply #5 is missing or
Absent
has failed.
PWR Supply 6
Power supply #6 is missing or
Absent
has failed.
Queue 0 Over
The congestion threshold for
Threshold
Queue 0 was exceeded.
Queue 1 Over
The congestion threshold for
Threshold
Queue 1was exceeded.
Queue 2 Over
The congestion threshold for
Threshold
Queue 2was exceeded.
Queue 3 Over
The congestion threshold for
Threshold
Queue 3 was exceeded.
Received External
User defined.
Alarm 1
Received External
User defined.
Alarm 2
Received External
User defined.
Alarm 3
(continued)
Managing System Alarms
Troubleshooting Steps
Information only. The card was not
stored in the database.
Download a new code image.
Be sure power supply #1 is plugged in.
Replace the power supply with an
operating unit.
Be sure power supply #2 is plugged in.
Replace the power supply with an
operating unit.
Be sure power supply #3 is plugged in.
Replace the power supply with an
operating unit.
Be sure power supply #4 is plugged in.
Replace the power supply with an
operating unit.
Be sure power supply #5 is plugged in.
Replace the power supply with an
operating unit.
Be sure power supply #6 is plugged in.
Replace the power supply with an
operating unit.
Check and correct VC connections.
Check and adjust VI shaper values.
Check and adjust incoming traffic
volume. Check for faulty IMA links
which may reduce traffic handling for a
group.
Check and correct VC connections.
Check and adjust VI shaper values.
Check and adjust incoming traffic
volume. Check for faulty IMA links
which may reduce traffic handling for a
group.
Check and correct VC connections.
Check and adjust VI shaper values.
Check and adjust incoming traffic
volume. Check for faulty IMA links
which may reduce traffic handling for a
group.
Check and correct VC connections.
Check and adjust VI shaper values.
Check and adjust incoming traffic
volume. Check for faulty IMA links
which may reduce traffic handling for a
group.
The leads connected to external alarm
1 have changed from the normal
setting.
The leads connected to external alarm
2 have changed from the normal
setting.
The leads connected to external alarm
3 have changed from the normal
setting.
209