208
C
6: P
B
HAPTER
ATH
UILDER
S700 D
P
IAGNOSTICS AND
ERFORMANCE
Table 41 MCPU and STX Module (System) Alarms (continued)
Alarm
Meaning
Card Config Failed
Cannot upload configuration
data to a card.
Card initialized.
Card initialized.
Card not installed
The required card is physically
not present. (STX)
Card Reconfig
Reconfiguration of the card
Failed
failed
Card Reconfigured
Card is reconfigured.
Cardtype Invalid
An unknown card type is
detected in a card slot.
Cardtype
The card type of a card slot in
mismatched
the database does not match
the card type of the same card
slot in the shelf.
Communication
Error during communication
Failed
between MCPU and a slot.
DS3/E3/OC3/CBR/
Interface clock has been
IMA/FAM Ref Clk
designated as the system clock,
Failed
and the interface clock has
failed.
Fan #1 failed
Fan #1 failed
Fan #2 failed
Fan #2 failed
Fan #3 failed
Fan #3 failed
Firmware Versions
The firmware versions in the
Mismatch
active and standby flash image
are not the same.
History Overflowed
Alarm history table has
overflowed. Alarms will
continue to be recorded but
will displace oldest alarms.
Id Prom Checksum
The internal checksum on the
Error
idprom of the indicated card is
incorrect.
Invalid DB Cardtype An unknown card type is
found in the database
Login Failure
Failed log -in. Someone failed
to log in to the shelf three
successive times.
Loss 8KHz Ref
The system reference clock was
Clock
lost.
Loss 25MHz ATM
STX hardware failure
Clock
Loss BITS Input
The system BITS clock has
Signal
failed.
(continued)
M
ONITORING
Troubleshooting Steps
Information only. Could indicate a
potential problem. You may need to
reset the card.
Information only.
Install the card.
Information only. Could indicate a
potential problem. You may need to
reset the card.
Information only. Could occur when
the card is plugged in or the system is
powered up.
Information only.
Information only.
Reseat the non-CPU slot. Replace the
MCPU if no improvement.
Check the physical connection. Check
for other alarms such as
LOS/LOF/LOCD. Check the physical
connection.
Replace the fan tray.
Replace the fan tray.
Replace the fan tray.
Information only.
Clear the history alarms table through
NMS or Telnet.
Have the idprom replaced with the
correct version. The system takes no
action if it recognizes the proper card
ID.
Information only.
Information only.
Try reassigning the clock—especially to
internal. This alarm may also indicate
an STX backplane problem.
Replace the STX card.
Correct the BITS clock input.