Port-based port mirroring

The following table describes the port-based Port Mirroring Configuration commands.
Table 171
Port Mirroring Configuration commands
Command
port-mirroring monitor-port
<port number> mirroring-port
<port number> {in|out|both}
no port-mirroring monitor-port
<port number> mirroring-port
<port number>
no port-mirroring monitor-port
<port number>
show port-mirroring

Uplink Failure Detection configuration

Uplink Failure Detection (UFD) supports network fault tolerance in network adapter teams. Use these
commands to configure a Failure Detection Pair of one Links to Monitor (LtM) group and one Links to
Disable (LtD) group. When UFD is enabled and a Failure Detection Pair is configured, the switch
automatically disables ports in the LtD if it detects a failure in the LtM. The failure conditions which are
monitored in the LtM group include port link state moving to down, or port state moving to Blocking if
Spanning Tree Protocol is enabled.
The following table describes the Uplink Failure Detection (UFD) Configuration commands.
Uplink Failure Detection Configuration commands
Table 172
Command
ufd enable
no ufd enable
show ufd
Description
Adds the port to be mirrored. This command also allows you to enter
the direction of the traffic. It is necessary to specify the direction
because:
If the source port of the frame matches the mirrored port and the
mirrored direction is ingress or both (ingress and egress), the frame
is sent to the mirrored port.
If the destination port of the frame matches the mirrored port and
the mirrored direction is egress or both, the frame is sent to the
monitoring port.
Command mode: Global configuration
Removes the mirrored port.
Command mode: Global configuration
Deletes this monitor port.
Command mode: Global configuration
Displays the current settings of the monitoring port.
Command mode: All except User EXEC
Description
Globally turns Uplink Failure Detection ON.
Command mode: Global configuration
Globally turns Uplink Failure Detection OFF.
Command mode: Global configuration
Displays the current Uplink Failure Detection configuration parameters.