Port-Based Port Mirroring; Uplink Failure Detection Configuration - HP 438031-B21 - 1:10Gb Ethernet BL-c Switch Command Reference Manual

Hp 1:10gb ethernet bl-c switch for c-class bladesystem command reference guide
Hide thumbs Also See for 438031-B21 - 1:10Gb Ethernet BL-c Switch:
Table of Contents

Advertisement

Port-based port mirroring

Command: /cfg/pmirr/monport <port number>
[Port 1 Menu]
The following table describes the port-based Port Mirroring Configuration Menu options.
Port Mirroring Configuration Menu options
Table 177
Command
add <mirrored port> in|out|both
rem <mirrored port>
delete
cur

Uplink Failure Detection configuration

Command: /cfg/ufd
[Uplink Failure Detection Menu]
Uplink Failure Detection (UFD) supports network fault tolerance in network adapter teams. Use this menu
to configure a Failure Detection Pair of one Links to Monitor (LtM) group and one Links to Disable (LtD)
group. When UFD is enabled and a Failure Detection Pair is configured, the switch automatically disables
ports in the LtD if it detects a failure in the LtM. The failure conditions which are monitored in the LtM
group include port link state moving to down, or port state moving to Blocking if Spanning Tree Protocol is
enabled.
The following table describes the Uplink Failure Detection (UFD) Configuration Menu options.
Uplink Failure Detection Configuration Menu options
Table 178
Command
fdp
on
add
- Add "Mirrored" port
rem
- Rem "Mirrored" port
delete
- Delete this "Monitor" port
cur
- Display current Port-based Port Mirroring configuration
fdp - Failure Detection Pair Menu
on
- Globally turn Uplink Failure Detection ON
off - Globally turn Uplink Failure Detection OFF
cur - Display current Uplink Failure Detection configuration
Description
Displays the Failure Detection Pair menu.
Globally turns Uplink Failure Detection ON.
Description
Adds the port to be mirrored. This command also allows you to enter
the direction of the traffic. It is necessary to specify the direction
because:
If the source port of the frame matches the mirrored port and the
mirrored direction is ingress or both (ingress and egress), the
frame is sent to the mirrored port.
If the destination port of the frame matches the mirrored port and
the mirrored direction is egress or both, the frame is sent to the
monitoring port.
Removes the mirrored port.
Deletes this monitored port.
Displays the current settings of the monitoring port.
Configuration Menu
186

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1:10gbe

Table of Contents