HP Brocade 4Gb SAN Installation Manual
Hide thumbs Also See for Brocade 4Gb SAN:
Table of Contents

Advertisement

Quick Links

Brocade 4Gb SAN Switch for HP
p-Class BladeSystem
installation guide
Part number: AA-RW1LA-TE
First edition: May 2005

Advertisement

Table of Contents
loading

Summary of Contents for HP Brocade 4Gb SAN

  • Page 1 Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide Part number: AA-RW1LA-TE First edition: May 2005...
  • Page 2 Hewlett-Packard. The information is provided “as is” without warranty of any kind and is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services.
  • Page 3: Table Of Contents

    HP-authorized reseller........
  • Page 4 3 Managing the 4Gb SAN Switch ......35 Management features of the 4Gb SAN Switch ........35 Maintaining the 4Gb SAN Switch .
  • Page 5 14 System specifications ..........55 Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 6 Contents...
  • Page 7: About This Guide

    About this guide This installation guide provides information to help you configure the Brocade 4Gb SAN Switch for HP p-Class BladeSystem (referred to hereafter as the 4Gb SAN Switch). “About this Guide” topics include: • Intended audience, page 7 • Related documentation, page 7 •...
  • Page 8: Document Conventions And Symbols

    Convention Element Medium blue text: Figure 1 Cross-reference links and e-mail addresses Medium blue, underlined text Web site addresses (http://www.hp.com) Bold font • Key names • Text typed into a GUI element, such as into a box • GUI elements that are clicked or selected, such as menu...
  • Page 9: Equipment Symbols

    To reduce the risk of personal INJURY or damage to the equipment, observe local occupational health and safety requirements and guidelines for manual material handling. Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 10: Hp Technical Support

    • Detailed, specific questions For continuous quality improvement, calls may be recorded or monitored. HP strongly recommends that customers sign up online using the Subscriber's choice web site: http://www.hp.com/go/e-updates. • Subscribing to this service provides you with email updates on the latest product enhancements, newest versions of drivers, and firmware documentation updates as well as instant access to numerous other product resources.
  • Page 11 • http://www.hp.com • http://www.hp.com/go/bladesystem • http://www.hp.com/go/support/ • http://www.docs.hp.com Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 12 About this guide...
  • Page 13: Overview

    • Universal and self-configuring ports, which are capable of becoming an F_Port (fabric enabled), FL_Port (fabric loop enabled), or E_Port (expansion port) • One RS-232 mini serial port, designed to connect to a Data Terminal Equipment (DTE) port Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 14: 4Gb San Switch Redundancy

    The 4Gb SAN Switch comes configured with one of three license options that complement existing HP product lines. Some 4Gb SAN Switches come with licenses that place limits on the number of domains that can be used. The three fabric licenses are: •...
  • Page 15 To determine the type of licensing included with your 4Gb SAN Switch, use the licenseshow command. switch:root> licenseshow XXXnnXXnXnnXXX: Fabric Watch license Release v5.0 license XXXnnXXnXnnXXX: Zoning license XXXnnXXnXnnXXX: Web license XXXnnXXnXnnXXX: 2 Domain Fabric license Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 16: 4Gb San Switch Characteristics

    4Gb SAN Switch characteristics The following subsections describe the physical characteristics of the 4Gb SAN Switch and some important requirements for proper operation. Port side of the 4Gb SAN Switch Figure 1 diagrams the ports of the 4Gb SAN Switch. Miniature Ethernet serial port...
  • Page 17: Isl Trunking Groups

    Server bay Switch port The rear side of the 4Gb SAN Switch connects to the HP p-Class BladeSystem I/O Blade (hereafter referred to as the Interconnect switch) to access the signal backplane for completion of a FC link connection to each server bay. Blowers inside the Interconnect switch push forced air for cooling through the 4Gb SAN Switch to exhaust at the rear of the enclosure.
  • Page 18: Supported Optional Features

    ISL Trunking is optional software that allows you to create trunking groups of ISLs between adjacent switches. ISL trunking is available on the Brocade 4Gb SAN Switch for HP BladeSystem, Power Pack, or by purchasing the optional license as described in the following section.
  • Page 19: Optional Hardware Kits

    16 m LC-to-SC FC cable C7530A* 5 m LC-to-SC multimode FC cable 221691-B21** 15 m LC-to-SC multimode FC cable 221691-B23** 30 m LC-to-SC multimode FC cable 221691-B26** 50 m LC-to-SC multimode FC cable 221691-B27** Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 20 Table 4 Available hardware (continued) Accessory Part number SC-female-to-SC-female adapter C7534A* 2 m LC-male-to-SC-male adapter kit C7534A* * Premerger HP part number ** Premerger Compaq part number Overview...
  • Page 21: Installing The 4Gb San Switch

    • Installing the 4Gb SAN Switch, page 25 • Server FC Port Connections, page 28 • Connecting the serial cable, page 28 • Configuring the 4Gb SAN Switch, page 29 Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 22: Shipping Carton Contents

    If necessary, convert this RS-232 cable to an RJ45 serial connector by removing the adapter on the end of the cable. Installation and safety considerations HP recommends installing the 4Gb SAN Switch into the back of the HP p-Class BladeSystem enclosure with the Interconnect switch power off. Installing the 4Gb SAN Switch...
  • Page 23: Electrical Considerations

    Verify that the air vents on the Interconnect switch and the 4Gb SAN Switch are not blocked or restricted. • Verify that the ambient air temperature at the front of the enclosure does not exceed 35°C (95°F) while the switch is operating. Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 24: Installing The Signal Conditioning Card

    Installing the signal conditioning card Power down the Interconnect switch. Remove the Interconnect switch by releasing the latch (1 and 2 in Figure 3) on the front and sliding it out of the enclosure (3). Figure 3 Interconnect switch removal Remove the cover of the Interconnect switch by loosening the thumbscrews (see Figure Figure 4...
  • Page 25: Installing The 4Gb San Switch

    Unpack the 4Gb SAN Switch and verify that all conditions listed in ”Installation and safety considerations” on page 22 are met. CAUTION: Do not block the 4Gb SAN Switch air vents. Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 26: Removing The Protective Foam From The Connector Guide Pins

    Remove the protective foam from the connector guide pins on the back of the 4Gb SAN Switch. Figure 6 Removing the protective foam from the connector guide pins. Plug the 4Gb SAN Switch into the back of the BladeSystem server enclosure; it will mate with the installed Interconnect switch.
  • Page 27: Installing An Sfp Transceiver(1) And Optical Cable (2)

    For instructions specific to cable type, refer to the cable manufacturer’s documentation. The cables used in trunking groups must meet specific requirements. For a list of these requirements, refer to the HP StorageWorks Fabric OS 5.0 features overview. Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 28: Server Fc Port Connections

    Server FC Port Connections The 4 Gb SAN Switch port connections to all blade servers except the BL40p are made through embedded pathways in the enclosure hardware. These require no transceivers or optical cables. The BL40p uses a standard HBA with optical transceivers. These ports are available at the rear of the enclosure, and must be connected to external ports of the 4 Gb SAN Switch using transceivers and optical cables.
  • Page 29: Configuring The 4Gb San Switch

    For instructions about configuring the switch to operate in a fabric containing switches from other vendors, refer to the HP StorageWorks Fabric OS 5.0 procedures user guide. For more information about the Command Line Interface (CLI), refer to the HP StorageWorks Fabric OS 5.0 command reference guide.
  • Page 30: Power Up The Switch And Log In

    Log in using the administrative account; the user name is admin and the default password is password. Up to two simultaneous admin sessions and four user sessions can be created. For details, refer to the HP StorageWorks Fabric OS 5.0 procedures user guide and the HP StorageWorks Fabric OS 5.0 command reference guide.
  • Page 31 Record the IP address on the label clearly displayed on the port side of the chassis. If the serial port is no longer required, log out of the serial console by typing exit and pressing Enter, and then remove the serial cable. Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 32: Create An Ethernet Connection And Log In

    Create an Ethernet connection and log in Create an Ethernet connection to the 4Gb SAN Switch: Connect an Ethernet cable to the Ethernet port and to the workstation or to an Ethernet network containing the workstation. After this connection is made, you can access the 4Gb SAN Switch remotely, by command line or by Advanced Web Tools.
  • Page 33: Verify The Configuration

    For specific instructions about how to back up the configuration, refer to the HP StorageWorks Fabric OS 5.0 procedures user guide. Back up the switch configuration to an FTP server by typing configupload and following the prompts.
  • Page 34 Installing the 4Gb SAN Switch...
  • Page 35: Managing The 4Gb San Switch

    Fibre Channel host driver. For a list of Fibre Channel hosts supported by the 4Gb SAN Switch, contact your HP representative. Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 36: 4Gb San Switch Management Features

    Ethernet or serial IP over FC supports up to two admin sessions connection and four user sessions simultaneously. For more information, refer to the HP StorageWorks Fabric OS 5.0 procedures user guide and the HP StorageWorks Fabric OS 5.0 command reference guide.
  • Page 37: Maintaining The 4Gb San Switch

    Non-bailed SFP transceivers are not recommended because they can be damaged by the removal process. Refer to the HP StorageWorks SAN design reference guide for a list of supported SFP transceivers and devices.
  • Page 38: Diagnostic Tests

    Diagnostic tests can temporarily lock the transmit and receive speed of the links during diagnostic testing. For information about specific diagnostic tests, refer to the HP StorageWorks Fabric OS 5.0 procedures user guide or type help followed by the name of the diagnostic test.
  • Page 39: Led Locations On The 4Gb San Switch

    Status LED Switch Status LED Figure 9 4Gb SAN Switch LED locations LED patterns Table 7 Table 8 summarize LED location, color, and meaning, as well as any recommended user response. Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 40: Switch Status Led Patterns

    Switch status LED patterns The system and power LED patterns are shown in Table 7 Table 7 Switch Status LED patterns during normal operation LED name, LED color Status of hardware Recommended action location Switch Status No light Switch is off, boot is Verify that switch is on and has completed not complete, or boot booting.
  • Page 41: Port Led Patterns

    Flickering green Port is online with traffic No action required. flowing through port. Steady amber Port is receiving light or No action required. signal carrier, but is not yet online. Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 42 Port is disabled as a result Enable the port using the of diagnostics or portEnable command; refer to (on 1 second, off 1 HP StorageWorks Fabric OS 5.0 portDisable second) command. command reference guide for more information. If the LEDs for all...
  • Page 43: Ethernet Led Patterns

    POST can be omitted for subsequent reboots by using the fastboot command. For more information about this command, refer to the HP StorageWorks Fabric OS 5.0 command reference guide. If you suspect a problem with the switch, enable POST to obtain more information on any failure.
  • Page 44: Boot

    Review the switch system log for errors. Any errors detected during POST are written to the system log, accessible through the errshow command. For information about all referenced commands and accessing the error log, refer to the HP StorageWorks Fabric OS 5.0 procedures user guide. For information about error messages, refer to the HP StorageWorks Fabric OS 5.0 diagnostic and system error messages reference...
  • Page 45: A Regulatory Compliance Notices

    Cet appareil numérique de la Classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. European Union notice This product complies with the following EU Directives: • Low Voltage Directive 73/23/EEC • EMC Directive 89/336/EEC Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 46: Laser Safety

    Compliance with these directives implies conformity to applicable harmonized European standards (European Norms) which are listed on the EU Declaration of Conformity issued by Hewlett-Packard for this product or product family. This compliance is indicated by the following conformity marking placed on the product: xxxx This marking is valid for non-Telecom products This marking is valid for EU non-harmonized Telecom products .
  • Page 47: Usage Restrictions

    There are no user-serviceable components inside. Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein. Allow only HP-authorized Service technicians to repair the unit. Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 48 Regulatory compliance notices...
  • Page 49: B Electrostatic Discharge

    Use conductive field service tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, contact HP customer service or have an HP-authorized reseller install the part. NOTE: For more information on static electricity, or for assistance with product installation, contact your HP-authorized reseller.
  • Page 50 Electrostatic discharge...
  • Page 51: C Technical Specifications

    300 m (984 ft) 1 Gb/sec 9μ 10 km (6.2 miles). Long Wave SFP transceivers are required. 2 Gb/sec 50μ 300 m (984 ft) 2 Gb/sec 62.5μ 150 m (492 ft) Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 52: External Fc Port Specifications

    Laser data transmission ranges (continued) Port speed Cable Short wavelength Long wavelength 2 Gb/sec 9μ 10 km (6.2 miles) without an HP Extended Fabrics license; 50 to 100 km with an HP Extended Fabrics license. 4Gb/sec 50μ 150 m (492 ft.) 4Gb/sec 62.5μ...
  • Page 53: Weight And Physical Dimensions

    SFP transceivers, because these can affect switch operability. They might not fit correctly and could void your warranty. For a complete list of supported devices, contact your local HP representative. Facility requirements To ensure correct operation of the 4Gb SAN Switch, the ambient air temperature at the front of the BladeSystem enclosure should not exceed 35°C while the switch is operating.
  • Page 54: Power Requirements

    LEDs, error messages, and Fabric Watch alerts indicate a problem. Enter the or Fabric Watch commands to view temperature status. tempshow Supported HBAs For a list of HBAs supported by the external ports of the 4Gb SAN Switch, contact your local HP Representative. Technical specifications...
  • Page 55: System Specifications

    There are a total of 12 Switch Ports. The 8 internal switch ports (0–7) will run at 2 Gb/sec and the 4 external ports (8–11) run at 4 Gb/sec for a total of 16+16 or 32 Gb/sec full duplex. Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 56 Table 14 System specifications (continued) Specification Description Port-to-port latency Less than 2 microseconds with no contention (destination port is free) EMC (electromagnetic compatibility) Emissions An operating 4Gb SAN Switch conforms to the emissions requirements specified by the following regulations: • FCC Rules &...
  • Page 57: Index

    DTE port trunking groups laser safety electrostatic discharge latency Canada interpreting activity FCC (USA) location equipment symbols patterns Ethernet connection licenseshow long wavelength, see LWL fabric license base full Brocade 4Gb SAN Switch for HP p-Class BladeSystem installation guide...
  • Page 58 SEEPROM serial connection supported transceiver installation SFP transceiver 22, 26, 27, removing short wavelength, see SWL signal conditioning card 22, 24, storage area network storage web site, HP Subscriber’s choice, HP symbols equipment symbols in text Technical specifications Index...

Table of Contents