OSSD
You can configure the Control Box to output OSSD pulses when a safety output is
Safety
inactive/high. OSSD pulses detect the ability of the Control Box to make safety outputs
Signals
active/low. When OSSD pulses are enabled for an output, a 1ms low pulse is generated on
the safety output once every 32ms. The safety system detects when an output is connected
to a supply and shuts down the robot.
The illustration below shows: the time between pulses on a channel (32ms), the pulse length
(1ms) and the time from a pulse on one channel to a pulse on the other channel (18ms)
To enable OSSD for Safety Output
1.
2.
3.
Default safety
The robot is delivered with a default configuration, which enables operation without any
configuration
additional safety equipment.
Connecting
Most applications require one or more extra emergency stop buttons. The illustration
emergency
below shows how one or more emergency stop buttons can be connected.
stop buttons
UR30 PolyScope X
In the Header, tap Installation and select Safety.
Under Safety, select I/O.
On the I/O screen, under Output Signal, select the desired OSSD checkbox. You must
assign the output signal to enable the OSSD checkboxes.
Safety
24V
EI0
24V
EI1
24V
SI0
24V
SI1
Safety
24V
EI0
24V
EI1
24V
SI0
24V
SI1
Safety
24V
EI0
24V
EI1
24V
SI0
24V
SI1
64