Password-Thresh - SMC Networks TigerStack II SMC8926EM Management Manual

24/48-port stackable layer 3 gigabit switch
Hide thumbs Also See for TigerStack II SMC8926EM:
Table of Contents

Advertisement

Command Usage
• If user input is detected within the timeout interval, the session is kept open;
otherwise the session is terminated.
• This command applies to both the local console and Telnet connections.
• The timeout for Telnet cannot be disabled.
• Using the command without specifying a timeout restores the default setting.
Example
To set the timeout to two minutes, enter this command:
Console(config-line)#exec-timeout 120
Console(config-line)#

password-thresh

This command sets the password intrusion threshold which limits the number of
failed logon attempts. Use the no form to remove the threshold value.
Syntax
password-thresh [threshold]
no password-thresh
threshold - The number of allowed password attempts.
(Range: 1-120; 0: no threshold)
Default Setting
The default value is three attempts.
Command Mode
Line Configuration
Command Usage
When the logon attempt threshold is reached, the system interface becomes
silent for a specified amount of time before allowing the next logon attempt.
(Use the silent-time command to set this interval.) When this threshold is
reached for Telnet, the Telnet logon interface shuts down.
Example
To set the password threshold to five attempts, enter this command:
Console(config-line)#password-thresh 5
Console(config-line)#
Related Commands
silent-time (23-22)
23
Line Commands
23-21