Using Hold Functions

The hold functions hold data for specific points during the measurement period, such as the
maximum or minimum value, and output those values at the end of the measurement period.
Flow of Operation
1
Selecting Hold Condition
for Measured Values
Selecting Hold Condition for Measured Values
The time period from the start of hold measurements to the end of hold measurements
is called the sampling period.
The value to be held during that sampling period is selected here.
The CLAMP value is output until the first sampling period is finished.
CLAMP value, p. 110
Any of the 5 settings shown in the table can be selected as the value to hold.
Selection
OFF
(Default)
P-H (Peak hold)
B-H (Bottom hold)
2
Setting the Trigger for
Measurement in Hold
Mode
Hold measurement is not performed. The measured value is always output.
Holds the maximum value during the sampling period. The output changes when
the sampling period is finished and is held then until the end of the next sampling
period.
Maximum
value
Current meas-
ured value
Sampling period
Holds the minimum value during the sampling period. The output changes at the
end of the sampling period and is held until the end of the next sampling period.
Current meas-
ured value
Sampling period
DETAILED SETTINGS
3
(If required)
Setting Delay Time
Details
Output
Minimum
value
Output
Section 5
ZX-E
81
Operation Manual