I/O Circuit Diagrams
NPN Amplifier Unit
Current output
(4 to 20 mA)
Current/voltage
output selector
Voltage
100 Ω
output
(±4 V)
PREPARATIONS FOR MEASUREMENT
Brown
12 to 24 V DC
HIGH judgement
output
White
Green
PASS judgement output
LOW judgement output
Gray
Blue
GND (0 V)
Pink
Judgement output hold input
Purple
Timing input
Orange Zero reset input
Red
Reset input
Linear output
Black
Shield
Linear ground
Load
Load
Load
12 to 24 V DC
Current output: 300 Ω max.
Load
Voltage output: 10 kΩ min.