Omron ZX1-LD Instruction Sheet

Omron ZX1-LD Instruction Sheet

Laser displacement sensor cmos type

Advertisement

Quick Links

Smart Sensor
ZX1-LD
□□
Laser Displacement Sensor CMOS Type
INSTRUCTION SHEET
Thank you for selecting an OMRON product. This sheet primarily
describes precautions required in installing and operating the product.
• A specialist who has the knowledge of electricity must treat the product.
• Please read this manual carefully, and use it correctly after thoroughly
understanding the product.
• Please keep this manual properly for future reference whenever
it is necessary.
©
OMRON Corporation 2011 All Rights Reserved.
* 0 1 9 9 5 6 0 - 4 D *
PRECAUTIONS ON SAFETY
● Meanings of Signal Words
Indicates a potentially hazardous situation which, if
not avoided, will result in minor or moderate injury,
WARNING
or may result in serious injury or death. Additionally
there may be significant property damage.
● Explanation of Signs
● Laser beam
Indicates caution on potential laser beam hazard.
● Do not disassemble
Indicates prohibition when there is a risk of minor injury from
electrical shock or other source if the product is disassembled.
● Alert Statements
WARNING
Do not expose your eyes to the laser radiation either directly
(i.e., after reflection from a mirror or shiny surface). Loss of
sight may possibly occur in case of the exposure to laser
high power density.
Do not disassemble the product. Doing so may cause the
laser beam to leak, resulting in the danger of visual
impairment.
SAFETY PRECAUTIONS FOR USING LASER EQUIPMENT
The ZX1-LD uses a laser as the light source. Lasers are classi ed based on EN standard (EN 60825-1)
■ Labeling on Laser Use
The ZX1-LD has the following WARNING label or explanatory label on the side of the sensors.
・ ZX1-LD□□
・ ZX1-LD□□L
Laser Warning Label
Explanatory Label
レーザ光
警告
ビームをのぞきこまないこと
クラス2レーザ製品
Max. 1.0mW
2.5ms
半導体レーザ
660nm
JIS C 6802 : 2011
Using in a country other than U.S.
・For countries other than Japan and U.S., warning labels
or explanatory labels must be replaced by English ones
(supplied with the product). EN60825-1 is provided for
products used in Europe, and the content of this
standard differs.
・The ZX1-LD is categorized as a Class 2 or Class 1
device as stipulated in EN60825-1:2007.
・ ZX1-LD□□
When using devices in which ZX1-LD is installed
Laser WARNING label
in the U.S., the devices are subjected to the U.S.
・ ZX1-LD□□L
FDA (Food and Drug Administration) laser
Explanatory Label
regulations. ZX1 series is classi ed into Class2 or
Class 1 by the standard of IEC/EN60825-1
according to deviations of Laser Notice NO.50 of
this standard, and reported to CDRH (Center for
Devices and Radiological Health).
Accession Number
(ZX1-LD□□ : 1210041-000)
(ZX1-LD□□L : 1210041-001)
FDA Certification label
Replace the WARNING label or explanatory label with the corresponding English label and
put the FDA Certi cation label. (supplied with the sensor)
Please make sure that the label are af xed at the correct locations as indicated.
・ ZX1-LD□□L
・ ZX1-LD□□
Laser Warning Label
Explanatory Label
(Class2 label / Aperture label)
PRECAUTIONS FOR SAFE USE
The following precautions must be observed, since they are essential to ensure safety in operation.
■ Installation Environment
• Do not use the Sensor in locations subject to explosive or ammable gases.
• To ensure safety in operation and maintenance, do not install the Sensor near high-voltage
equipment or power devices.
■ Power Supply and Wiring
• Do not impose voltage exceeding the rated voltage: 10 to 30 VDC, including 10% ripple (p-p).
• When supplying power to the Sensor, make sure that the polarity of the power is correct, and do
not connect to an AC power supply.
• Do not short-circuit the load for the open collector output. Short-circuiting the load may cause
re or damage on the Sensor.
• Connect the load correctly. Short-circuiting the load may cause re or damage on the Sensor.
• Keep the load within the rated range. Overloading may result in re or damage on the Sensor.
• Wire the product cable separately from high-voltage or power lines. Placing them in the same
wiring or the same duct may cause induction, resulting in the product malfunction or damage.
• Always turn off the power of the Sensor before connecting or disconnecting the cable or
connector.
• Do not use the Sensor for the safety circuits in nuclear power or life-critical applications.
• Implement safety measures e.g. fail-safe circuits.
■ Installation
• Make sure that all installation screws must be tighten securely.
Tightening torque: M3, 0.5N·m (ZX1-LD50□□/ZX1-LD100□□)
M4, 1.2N·m (ZX1-LD300□□/ZX1-LD600□□)
■ Others
• Do not attempt to disassemble, deform by pressure, incinerate, repair, or modify this product.
• When disposing of the product, treat as industrial waste.
• If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or
smoke, immediately stop using the product, turn off the power, and consult your dealer.
PRECAUTIONS FOR CORRECT USE
■ Installation Location
Do not install the product in locations subjected to the following conditions:
• Surrounding air temperature outside the rating
• Rapid temperature uctuations (causing condensation)
• Relative humidity outside the range of 35 to 85%
• Presence of corrosive or ammable gases
• Presence of dust, salt, or iron particles
• Direct vibration or shock
• Re ection of intense light (such as other laser beams, electric arc-welding machines, or
ultra-violet light)
• Direct sunlight or near heaters
• Water, oil, or chemical fumes or spray, or mist atmospheres
• Strong magnetic or electric eld
• In the water, rain, or outdoors
■ Power Supply and Wiring
• Do not supply the power to the Sensor before checking the I/O wiring.
• Ground the FG terminal when using a commercially-available switching regulator.
• If the power supply line is subject to surges, connect a surge absorber that meets the conditions
of the operating environment.
• Do not turn ON the power after wiring before making sure that the power supply is connected
correctly; there are no faulty connections, e.g. load short-circuits; the load current is correct.
Incorrect wiring may result in failure.
• Use a ZX0-XC□R Extension Cable (sold separately) to extend the Sensor's cable. Use only one
cable. Do not extend the cable for the Sensor to a length exceeding 20 m.
• The display and indicators turn ON after approx. 2.5 seconds after the power is turned ON.
■ Warming Up
• After turning ON the power, allow the Sensor to warm up for approx. 30 minutes prior to use.
The circuitry is not stable immediately after turning the power ON, and the values gradually
change until the Sensor is completely warmed up. When using LD-OFF input for a long period
of time, perform warmng up for more than 30 minutes after cancelling LD-OFF.
■ Maintenance and Inspection
• Always turn OFF the power of the Sensor before connecting or disconnecting the cable or for
making adjustment.
• Do not use thinner, alcohol, benzene, acetone, or kerosene to clean the Sensor.
• If considerable foreign matter or dust collects on the glass surface of the front of Sensor, use a
blower brush (for camera lenses) to blow off the foreign matter. Avoid blowing it off with your
breath. For a small amount of foreign matter or dust, gently wipe with a soft cloth. Do not wipe
hard. The damaged glass surface may result in detection errors.
■ Sensing Object
The product cannot accurately measure the following types of objects: Transparent objects,
objects with an extremely low re ective sensor ratio, objects smaller than the spot diameter,
objects with a large curvature, excessively inclined objects, etc.
Checking the Package Content
• Sensor: 1
• Instruction sheet (this sheet): 1 each (Japanese and English)
• FDA Certification label : 1
• Laser Warning Label : 1 each (Japanese and English)
(The explanatory labels are attached to ZX1-LD□□L instead of the warning explanation labels.)
-1-
1
Installation
1-1
Dimensions
■ ZX1-LD50□/ZX1-LD100□
Reference surface
Emitter center position mark
Emitter axis
Reference surface
2-3.2 dia.
2
47
(Mounting hole)
24.1
35.3
Reference surface
15.1
Receiver
axis
Emitter
axis
L*
10.1
11.7
10.5
Emitter center
Emitter center
position mark
Vinyl insulated round-shaped robot cable
* ZX1-LD50□: L=50, A=21°
Dia 6.5 9-wire (cross section of conductor:
ZX1-LD100□: L=100, A=11.5°
0.125 mm
2
/insulator diameter: 0.7 mm)
Standard length: 2 m
Root section bending disabled length: 0 mm
■ ZX1-LD300□/ZX1-LD600□
Minimum bending radius: 39 mm
Reference surface
Emitter center position mark
Emitter
axis
2-4.5 dia.
(Mounting hole)
Reference surface
1.9
50.1
Reference surface
27.2
45.6
17
Receiver
axis
Emitter
axis
10.1
L*
15.5
13.6
Emitter center
Emitter center
position mark
Vinyl insulated round-shaped robot cable
Dia 6.5 9-wire (cross section of conductor:
* ZX1-LD300: L=300, A=6.6°
0.125 mm
2
/insulator diameter: 0.7 mm)
ZX1-LD600: L=600, A=3.4°
Standard length: 2 m
Root section bending disabled length: 0 mm
<Connector Joint Model>
Minimum bending radius: 39 mm
■ ZX1-LD50□6/ZX1-LD100□6
ZX1-LD300□6/ZX1-LD600□6
Vinyl insulated round-shaped robot cable
Dia 6.5 9-wire (cross section of conductor:
0.125 mm
2
/insulator diameter: 0.7 mm)
Standard length: 0.5 m
Sensor root section bending disabled length: 0 mm
Connector section bending disabled length: 40 mm
Minimum bending radius: 39 mm
39.8
<Extension Cable>
37.3
L*
* The length of L is as follows:
ZX0-XC10R: 10 m, ZX0-XC20R: 20 m
The extension cable is the robot cable, the same as the cable of the Sensor Unit.
1-2
Mounting Sensor
To mount ZX1-LD50 and ZX1-LD100□, use M3 screws (tightening torque: 0.5 N·m) and
ZX1-LD300□ and ZX1-LD600, M4 screws (tightening torque: 1.2 N·m).
Mounting hole dimensions (Unit: mm)
Emitter/Receiver direction
Reference
surface
Reference
Reference
surface
surface
23.6±0.1
35.3±0.1
ZX1-LD50□
ZX1-LD300□
ZX1-LD100□
ZX1-LD600□
Do not touch the sensor emitter and receiver sections. Correct detection may
not be possible if fingerprints are attached to these areas. If fingers have
inadvertently touched the areas, wipe the areas using a soft, clean cloth.
■ Caution on Mounting Direction
<Detection Near the Wall Surface>
(Unit: mm)
The Sensor is less
The Sensor is easily in uenced by
in uenced by ambient
ambient lighting, which may cause
detection value variations. *
lighting.
<Detection of Workpiece with Level Difference>
18.7
2.5
Stable detection is possible
regardless of level difference.
* Before performing tuning, apply mat paint on the wall surface or turn ON the background suppression
function to avoid laser light re ection.
Refer to " 5. Background suppression function,
Detailed Settings"
1-3
Wiring
The table below shows individual external I/O wires and their roles.
Wire color
Name
Connect to 10 to 30 VDC (including 10% ripple (p-p)). Used as the
Brown
Power supply
common I/Os terminal for all I/O except monitor output for a PNP output type.
0-V power supply terminal. Used as the common I/Os terminal
Blue
GND
for all I/O except monitor output for an NPN output type.
White
OUT1 Judgment output
Outputs the CH1 judgment result.
Green
OUT2 Judgment output
Outputs the CH2 judgment result.
Outputs the current value according to the measurement result.
21.3
3
Black
Analog output
(4 to 20 mA)
0-V ground line for monitor output.
Shield
Analog GND
Connect this line separately from the blue (0 V) GND.
[Important] Be sure to connect to blue (0 V).
Orange
TUNE1 input
Inputs tuning to CH1.
Pink
TUNE2 input
Inputs tuning to CH2.
Purple
Zero reset input
Used to execute or cancel zero reset.
ON: Laser turns OFF (radiation stop). In this state, analog output, digital
Red
LD-OFF input
display, judgment output and judgment output display are output based on
keep function settings. The digital display shows [
The individual wire colors and roles are the same between pre-wired and
connector joint models.
Wire the Sensor correctly. Unused wires must be insulated. Incorrect wiring may
result in damage to the Sensor.
■ I/O Circuit Diagram <NPN Output Type>
Brown: 10 to 30 VDC
White: OUT1
judgment output
Green: OUT2
judgment output
Blue: GND (0 V)
Orange: TUNE1 input
Pink: TUNE2 input
Purple: Zero reset input
Red: LD-OFF input
Current output
4 to 20 mA
Black: Analog output
Shield: Analog GND
■ I/O Circuit Diagram <PNP Output Type>
Brown: 10 to 30 VDC
White: OUT1
judgment output
Reference
Green: OUT2
surface
judgment output
Blue: GND (0 V)
Orange: TUNE1
Pink: TUNE2
Purple: Zero reset input
30.1±0.1
Red: LD-OFF input
45.6±0.1
Current output
4 to 20 mA
Black: Analog output
Shield: Analog GND
-2-
<Cavity Detection>
Detection is not possible if
the emitter or receiver section
is blocked.
Level difference may cause
an abnormal detection value.
Role
].
10 to 30 VDC
Load
300
max.
10 to
30 VDC
Load
300
max.

Advertisement

loading

Summary of Contents for Omron ZX1-LD

  • Page 1 Connector section bending disabled length: 40 mm The ZX1-LD uses a laser as the light source. Lasers are classi ed based on EN standard (EN 60825-1) Minimum bending radius: 39 mm • Do not turn ON the power after wiring before making sure that the power supply is connected 39.8...
  • Page 2 (1) Switch Channel to Set Threshold (4) Set Upper Limit and Lower Limit (Using Area Output) Settings 1. Hold the button (5 sec. or longer) until [ ] blinks rapidly without a workpiece. TUNE ● 2-point Area Tuning Refer to " 7. Area Output, Detailed Settings"...
  • Page 3 Convenient Setting Features Detailed Settings Function Setting Description Function Setting Description To enter the Menu Setting mode, hold button for at least 3 seconds. (1) Reset the Present Distance to "0" MODE The Menu Setting mode provides the following function settings. 5.
  • Page 4 Correct measured values may not be obtained if a workpiece with smaller diameter than the spot size is detected. Alexandra Technopark, Singapore 119967 *2. It shows the error in relation to the ideal curve of the displacement output when measuring OMRON's standard physical object (white ceramic) under the environment at 25°C.