APPENDICES
1. Resolution: The resolution is the deviation ( ± 3 σ ) in the linear output when connected to the Amplifier Unit.
Notes:
The above values indicate the deviations observed 30 minutes after the power is turned ON. (The resolu-
tion is measured with the standard sensing object at 1/2 of the measurement distance range, with the
Amplifier Unit set for the maximum average count of 4,096 per period.)
The resolution is given as the repeat accuracy for a stationary workpiece, and is not an indication of the
distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
2. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring
the standard sensing object (varies with the object being measured).
3. The value following linearity adjustment using a standard sensing object for an ambient temperature of
25 ° C.
4. Temperature characteristic: At the same temperature as the Amplifier Unit, and with the standard sensing
object at 1/2 of the measurement distance range.
5. Temperature characteristic: The temperature of the Sensor Head only, and with the standard sensing
object at 1/2 of the measurement distance range.
6. Do not use in moist environments because the case is not waterproof.
7. Even when operated within the specified temperature range, using in locations subject to extreme temper-
ature fluctuations may result in deterioration of Sensor characteristics.