Omron ZX-E Operation Manual page 65

Zx-e smart sensors series inductive displacement type
Hide thumbs Also See for ZX-E:
Table of Contents

Advertisement

Mounting Sensor to Press
Mount the Sensor Head and the sensing object to the press machine. Refer to the fol-
lowing diagram for the required mounting jig.
Installing Sensor Heads, p. 30
Use a ferrous sensing object and one that is as large as or larger than the standard sensing object.
Sensing object, p. 143
Adjusting Detection Position
Adjust the position of the Sensor Head so that when the press machine is set at the
bottom deadpoint position, the distance between the Sensor Head and the sensing
object is about half of the measurement distance. Refer to the Amplifier Unit display
while adjusting the Sensor Head position.
Measurement Distance, p. 143
MAIN APPLICATIONS AND SETTING METHODS
Sensing object
Section 4