Omron ZX-E Operation Manual page 88

Zx-e smart sensors series inductive displacement type
Hide thumbs Also See for ZX-E:
Table of Contents

Advertisement

Section 5
DETAILED SETTINGS
Setting Delay Time
Delay time is set to ignore measurements immediately after the timing input. This is
useful for avoiding bounding during device startup and the influence of machine vibra-
tion.
The delay time (the delay between timing input and the start of sampling) and the sam-
pling period can be set.
The default delay time setting is OFF.
Make the sum of the delay time and sampling period less than the timing input ON interval.
If the next timing input for measurement is received before the delay and sampling period have
passed, that timing input will be ignored and will not be reflected in the sampling.
Moving to Delay Hold (H-DLY)
1.
Use the LEFT and RIGHT Keys to display H-
DLY on the main display.
H-DLY will not be displayed if the delay conditions are set
to OFF.
2.
Press the UP or DOWN Key.
The sub-display will flash.
3.
Use the UP and DOWN Keys to display ON.
4.
Press the ENT Key.
The settings mode for the H-DLY function is now
enabled.
ZX-E
86
Operation Manual
Delay time
Timing input
Smpling period
Timing input ignored.
Timing input used.
Delay time

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zx-edr5tZx-ed01tZx-ed02tZx-em02tZx-em07mtZx-em02ht

Table of Contents