Section 2
PREPARATIONS FOR MEASUREMENT
PNP Amplifier Unit
Current/voltage
output selector
ZX-E
40
Operation Manual
Brown
White
Green
Gray
Blue
Pink
Purple
Orange Zero reset input
Red
Current output
(4 to 20 mA)
Black
Voltage
100 Ω
output
(±4 V)
Shield
12 to 24 V DC
HIGH judgement
output
PASS judgement output
LOW judgement output
Load
Load
GND (0 V)
Judgement output hold input
Timing input
Reset input
Linear output
Current output: 300 Ω max.
Load
Voltage output: 10 kΩ min.
Linear ground
12 to
24
V DC
Load