Preventing Mutual Interference between Sensors
Sensor Heads can be installed adjacent to each other if the mutual interference preven-
tion function is used. Mutual interference can be prevented for up to 5 Amplifier Units.
Set the same number of samples to average for all Amplifier Units.
Response time is longer when the mutual interference prevention function is used.
• Response time = (15 ms + response time based on set number of samples to aver-
age) × number of Amplifier Units
• If the calculation function is also used, the response time will be longer again by
approximately 15 ms.
• Response times for external input signals also become longer by the same amount.
Response time, p. 139