Omron ZX-E Operation Manual page 143

Zx-e smart sensors series inductive displacement type
Hide thumbs Also See for ZX-E:
Table of Contents

Advertisement

Functions
Measured value
display
Present value dis-
play
Output value dis-
play
Set value display
Resolution display
ENABLE indicator
Zero reset indica-
tor
Power ON indica-
tor
Judgement indica-
tor
ECO mode
Display reverse
Indications
Judgement indicators: HIGH (orange), PASS (green), LOW (yellow), 7-segment main display
(red), 7-segment sub-display (yellow), power ON (green), zero reset (green), enable (green)
0.5% F.S. of linear output value at ± 20% of power supply voltage
Voltage influence
(including Sensor)
12 to 24 VDC ± 10%, Ripple (p-p): 10% max.
Power supply
voltage
Power consumption 3.4 W max. (Sensor connected)
(Power supply voltage: 24 V, Current consumption: 140 mA max.)
Operating and storage: 0 to 50 ° C (with no icing or condensation)
Ambient
temperature
Ambient humidity
Operating and storage: 35% to 85% (with no condensation)
20 M Ω min. at 500 VDC
Insulation
resistance
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min
Vibration resistance
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions
(destructive)
Shock resistance
300 m/s
(destructive)
Connection method Prewired (standard cable length: 2 m)
Weight (packed
Approx. 350 g
state)
Materials
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Accessories
Instruction sheet
Notes:
1. The response speed of the linear output is calculated as the measurement period x (No. of samples to
average setting + 1).
The response speed of the judgement outputs is calculated as the measurement period x (No. of samples
to average setting + 1).
2. The output can be switched between current output and voltage output using a switch on the bottom of the
Amplifier Unit.
3. Setting is possible via the monitor focus function.
4. A Calculating Unit is required.
ZX-EDA11
Display digit limit
Zero reset
Zero reset memory
Previous value compari-
son
Initialization
Linearity initialization
Teaching
Direct threshold value
setting
Hysteresis width setting
Scaling
Linearity adjustment
2
3 times each in six directions (up/down, left/right, forward/backward)
APPENDICES
ZX-EDA41
Monitor focus
One-shot timer
Linear output correc-
Timing inputs
tion
Self-up trigger
Peak hold
Self-down trigger
Bottom hold
(A-B) calculations
Sample hold
(See note 4.)
Peak-to-peak hold
(A+B) calculations
(See note 4.)
Average hold
Thickness calculation
Delay hold
(See note 4.)
Delay time setting
Mutual interference
ON-delay timer
prevention
OFF-delay timer
(See note 4.)
Key lock
Clamp value setting
ZX-E
141
Operation Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zx-edr5tZx-ed01tZx-ed02tZx-em02tZx-em07mtZx-em02ht