Moving to FUN and SPCL
1.
Set the mode switch to FUN.
2.
Use the LEFT and RIGHT Keys to display
SPCL on the main display.
Moving to ZRMEM
3.
Press the UP or DOWN Key.
The sub-display will flash.
4.
Use the UP and DOWN Keys to display ETC
or ALL.
5.
Press the ENT Key.
6.
Use the LEFT and RIGHT Keys to display
ZRMEM on the main display.
Selecting Whether or Not to Enable Zero Reset Memory
7.
Press the UP or DOWN Key.
The sub-display will flash.
8.
Use the UP and DOWN Keys to select ON or
OFF.
ON: Zero reset memory enabled (default)
OFF: Zero reset memory disabled
9.
Press the ENT Key to confirm the selection.
The zero reset memory setting will be registered.