Key Lock Function - Omron ZX-E Operation Manual

Zx-e smart sensors series inductive displacement type
Hide thumbs Also See for ZX-E:
Table of Contents

Advertisement

Section 6
AUXILIARY FUNCTIONS

Key Lock Function

The key lock function disables all Amplifier Unit keys. Once the keys have been disabled, no
key input will be accepted until the lock is released. This function is useful to prevent
inadvertent changes to settings.
The mode and threshold switches are still enabled even when the key lock function is ON.
Setting the Key Lock
1.
Set the mode switch to FUN.
2.
Hold down the UP, DOWN, RIGHT, and LEFT
Keys at the same time.
LOCK will be displayed on the main display and "-----" will
be displayed on the sub-display.
3.
Release the keys once OK is displayed on the
sub-display.
The keys will be locked.
Releasing the Key Lock
1.
Set the mode switch to FUN.
2.
Hold down the UP, DOWN, RIGHT, and LEFT
Keys at the same time.
FREE will be displayed on the main display and "-----" will
be displayed on the sub-display.
3.
Release the keys once OK is displayed on the
sub-display.
The key lock will be released.
ZX-E
132
Operation Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zx-edr5tZx-ed01tZx-ed02tZx-em02tZx-em07mtZx-em02ht

Table of Contents