Setting Threshold Values
3.
Start measurement.
Measurement will continue while the ENT and RIGHT
Keys are held down.
AUTOT will flash on the sub-display after the keys have
been pressed for one second.
4.
Release the ENT and RIGHT Keys to end
measurement.
The maximum measured value during the measurement
period will be set as the HIGH threshold value and the
minimum will be set as the LOW threshold value.
The new threshold value (either HIGH or LOW, depend-
ing on the threshold switch setting) will be displayed on
the sub-display.
If ERRLH is displayed: p. 98
The threshold values set using automatic teaching can be changed using direct input.
This is useful when setting judgement tolerances for measured values.
p. 98