Omron ZX-E Operation Manual page 33

Zx-e smart sensors series inductive displacement type
Hide thumbs Also See for ZX-E:
Table of Contents

Advertisement

Installation Distance
Mount the Sensor Head so that the distance between the Sensor Head and the sens-
ing object is approximately half of the measurement distance.
Example: ZX-ED01T Sensor Head
Measurement distance: 0 to 1 mm
Use a ferrous sensing object larger than a standard sensing object. If a smaller-than-standard
sensing object or a non-ferrous object is used, the predetermined characteristics may not be
obtained.
Characteristic Data, p. 148
Influence of Surrounding Metal
Separate the Sensor Head from surrounding metals by at least the distances shown in
the following diagram.
Dia.
Model
ZX-EDR5T
ZX-ED01T
ZX-ED02T
ZX-EM02T
ZX-EM07MT
ZX-EV04T
ZX-EM02HT
PREPARATIONS FOR MEASUREMENT
0.5 mm
Sensing object: Ferrous object 18 × 18 mm or larger
(Unit: mm)
Dia. A
B
8
9
10
9
12
9
12
9
55
20
16 × 32
4.8
18
9
Section 2
ZX-E
31
Operation Manual