Timer and Counter Instructions
Applicable Program Areas
Operands
Operand Specifications
Block program areas
Not allowed
OK
D1: Completion Flag
Bit 0 of D1 acts as the Completion Flag for TIML(542)/TIMLX(553).
15
D1
Do not use.
D2: PV Word
D2+1 and D2 contain the 8-digit binary or BCD PV. (D2 and D2+1 must be in
the same data area.) The PV can range from #00000000 to #99999999 for
TIML(542) and &00000000 to &4294967295 (decimal) or #00000000 to
#FFFFFFFF (hexadecimal) for TIMLX(553).
D2+1
D2
S: SV Word
S+1 and S contain the 8-digit binary or BCD SV. (S and S+1 must be in the
same data area.) The SV must be between #00000000 to #99999999 for
TIML(542) and &00000000 to &4294967294 (decimal) or #00000000 to
#FFFFFFFF (hexadecimal) for TIMLX(553).
S+1
S
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Counter Area
DM Area
Indirect DM addresses
in binary
Indirect DM addresses
in BCD
Constants
Data Registers
Step program areas
Subroutines
OK
0
Completion Flag
D2
S
D1
CIO 0 to
CIO 0 to CIO 6142
CIO 6143
W0 to W511
W0 to W510
H0 to H511
H0 to H510
A448 to A959
A448 to A958
---
---
---
---
D0 to D32767
D0 to D32766
@ D0 to @ D32767
*D0 to *D32767
---
---
Section 3-5
Interrupt tasks
Not allowed
D2
S
A0 to A958
T0000 to T4094
C0000 to C4094
BCD:
#00000000 to
99999999 (BCD)
"&" cannot be
used.
Binary:
&00000000 to
&4294967295
(decimal) or
#00000000 to
#FFFFFFFF (hex)